9SOUNDER - DB3B TM264 June 2019 www.eaton.com
Sounder - DB3B
English
If the unit requires cleaning, then only clean exterior with
a damp cloth to avoid electro-static charge build up.
If a unit fault should occur, then the unit can be repaired
by MEDC.
If you acquired a significant quantity of units, then it
is recommended that spares are also made available.
Please discuss your requirements with the Technical Sales
Engineers at MEDC.
6.0 Certification/approvals
lECEx units
Gas (G) certified units
Certified to IEC60079-0, IEC60079-1 and IEC60079-7
Ex d IIC unit (IEC certification No. lECEx BAS 13.0112X)
Ex db IIC T
G
(T
amb
.) Gb
Ex de IIC unit (IEC certification No. IECEx BAS 13.0114X)
Ex db eb IIC T
G
(T
amb.
) Gb
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The IECEx certificate and product label carry the IECEx
equipment protection level marking:
Gb
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Gas & Dust (GD) certified units
Certified to IEC60079-0, IEC60079-1, IEC60079-7 and
IEC60079-31
Ex d IIIC unit (IEC certification No. IECEx BAS 13.0113X)
Ex db IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Ex de IIIC unit (IEC certification No. IECEx BAS 13.0115X
Ex db eb IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
*depending on outer flare type (Short flare – IP65, Long
flare – IP66)
See special conditions for safe use for ambient tempera-
ture ranges and T-ratings.
The IECEx certificate and product label carry the IECEx
equipment protection level markings:
Gb and Db
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Db signifies suitability for use in a Zone 21 surface
industries area in the presence of dust.
ATEX units
Gas (G) certified units
Certified to EN60079-0, EN60079-1 and EN60079-7
Ex d IIC unit (ATEX certification No. Baseefa
13ATEX0229X)
Ex db IIC T
G
(T
amb.
) Gb
Ex de IIC unit
(ATEX certification No. Baseefa 13ATEX0232X)
Ex db eb IIC T
G
(T
amb.
) Gb
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The ATEX certificate and product label carry the ATEX group
and category marking:
II 2 G
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
Gas & dust (GD) certified units
Certified to EN60079-0, EN60079-1, EN60079-7 and
EN60079-31
Ex d IIIC unit (ATEX certification No. Baseefa13ATEX0231X)
Ex db IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Ex de IIIC unit (ATEX certification No. Baseefa13ATEX0233X)
Ex db eb IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
*depending on outer flare type (Short flare – IP65, Long
flare – IP66).
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The ATEX certificate and product label carry the ATEX
group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
D Signifies suitability for use in the presence of dust
These units also have the following approvals:
Ingress protection: Ex d & Ex e terminal chambers – IP66
& IP67 to IEC60529