2. Programming Concepts
MN05003003E For more information visit: www.eaton.com
2-65
Special D
Function
ELC
-PB
ELCB
-PB
ELC
-PC
-PA
-PH
ELCM
-PH
- PA
ELC
-PV
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Type Latched
Factory
setting
D1242
When interrupt I500/I501/I300/I301
occurs, D1242 stores the low Word of
high-speed counter.
- - Y - 0 0 - R
NO
0
D1243
When interrupt I500/I501/I300/I301
occurs, D1243 stores the high Word of
high-speed counter.
- - Y - 0 0 - R
NO
0
D1244
Idle time (pulse number) setting of CH0
(Y0, Y1) The function is disabled if set
value0.
- - Y - 0 - - R/W NO 0
D1245
Idle time (pulse number) setting of CH1
(Y2, Y3) The function is disabled if set
value0.
- - Y - 0 - - R/W
NO
0
D1249
Set value for COM1 (RS-232) data
receiving time-out (Unit: 1ms, min.
50ms, value smaller than 50ms will be
regarded as 50ms) (only applicable for
MODRW/RS instruction) In RS
instruction, no time-out setting if “0” is
specified.
- - Y - 0 - - R/W NO 0
D1250
COM1 (RS-232) communication error
code (only applicable for MODRW/RS
instruction)
- - Y - 0 - - R/W
NO
0
D1252
Set value for COM3 (RS-485) data
receiving time-out (Unit: 1ms, min.
50ms, value smaller than 50ms will be
regarded as 50ms) (only applicable for
MODRW/RS instruction) In RS
instruction, no time-out setting if “0” is
specified
- - Y - 50 - - R/W
NO
50
D1253
COM3 (RS-485) communication error
code (only applicable for MODRW/RS
instruction)
- - Y - 0 - - R/W
NO
0
D1255
COM3 (RS-485) ELC communication
address
- - Y - 50 - - R/W
YES
1
D1256
D1295
MODRW instruction of COM2 (RS-
485) is built-in. The characters sent
during execution are saved in
D1256~D1295. User can check
according to the content of these
registers.
Y Y Y Y 0 - - R NO 0
D1296
D1311
MODRW instruction of COM2 (RS-
485) is built-in. The ELC system will
convert ASCII content of the register to
HEX and save it in D1296 – D1311.
Y Y Y Y 0 - - R NO 0
D1313
Perpetual calendar (RTC) second
00~59
- Y Y Y 0 - - R/W NO 0
D1314
Perpetual calendar (RTC) minute
00~59
- Y Y Y 0 - - R/W NO 0
D1315
Perpetual calendar (RTC) hour 00~23
- Y Y Y 0 - - R/W NO 0
D1316
Perpetual calendar (RTC) day 01~31
- Y Y Y 0 - - R/W NO 1
D1317
Perpetual calendar (RTC) month
01~12
- Y YY Y 0 - - R/W NO 1
D1318
Perpetual calendar (RTC) week 1~7
- Y Y Y 0 - - R/W NO 6
D1319
Perpetual calendar (RTC) year 00~99
- Y Y Y 0 - - R/W NO 0