EasyManua.ls Logo

Eaton i-on40 - 6 Technical Specification; General; Capacities; Security

Eaton i-on40
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
i-on40
Page 26
6. Technical Specification
General
Product name
i-on40.
Product
Description
40 zone hybrid endstation with
remote keypads.
Manufacturer
Eaton’s Security Business.
Environmental
Class II.
Operating
temperature
Tested -10 to +55°C.
Humidity
0 to 93% RH, non-condensing.
Case material
ABS LG-AF342.
Dimensions:
Control unit
384 x 245 x 94, mm HxWxD.
I-KP01
115 x 156 x 34, mm HxWxD
KEY-
K01/KP01/KPZ01
128 x 128 x 29, mm HxWxD
Weight:
Control unit
2.2 kg (without stand-by
battery).
i-KP01
0.26 kg
KEY-K01
0.19 kg
KEY-KP01
0.19 kg
KEY-KPZ01
0.19 kg
Capacities
Zones
16 wired, 24 radio
Keypads
4 wired, 4 radio
Outputs
16 wired (comprising two
voltage free contacts, 14
transistorised of which 12 are
provided on separate wiring
harnesses).
8 radio output channels.
Internal Clock
±10 minutes over one year
(depending on the accuracy of
the mains supply frequency).
Remote
controls
50
Panic Alarms
50
External Radio
Sirens
4
Plug on
communication
modules
One only
WAMs
4
Log capacity
Up to 1,000 events: 750
mandatory events, 250 non-
mandatory. Stored in EEPROM
memory, available for at least
10 years without power.
Security
Security Grade
Grade 2.
Radio detector
differs
16,777,214 (2
24
-2).
Radio
Supervision
Programmable.
Number of
50 plus installer
access codes
Access code
differs
10,000 differs. 4 digit codes, all
four digits may be any number
0 to 9.
Code blocking
Blocked for 90s after four
incorrect codes (or prox tags)
in series. Blocked for a further
90s after each additional
incorrect code or prox tag, until
next correct code or prox tag
entered.
Proximity tag
differs
4,294,967,296 (2
32
)
Radio
Radio Section
Operating frequency
868.6625MHz Narrowband.
EN 300 220-3.
EN 300 330-2
Transmitter
range
The range of the transmitters
compatible with this control unit
depends on the environment in
which they are installed. As a
guideline, most transmitters will
work up 200m range in free
space conditions.
Power Supply
Integrated power supply. Monitoring includes
mains fail, battery low voltage, aux output low
voltage, battery failure.
Power supply type:
A
Mains power supply
requirements:
230VAC +10%/-15%,
170mA max, 50Hz
Total power supply
capacity:
1.5A
Aux power supply:
1.1A capability
14.4V output:
300mA capability
Comms power supply:
500mA capability
Keypad bus power
supply rated output:
500mA capability
Note: Under EN50131-6 the maximum total load
that can be drawn from these outputs is 270mA
i.e. the aux current that can be supplied for 12hrs
by a 7 A-h battery under normal operating
conditions.
EN50131-6 ratings:
PSU rated output:
270mA max
Independent power
outputs (Normal
operating conditions):
Total not to exceed
270mA for 7 Ah battery
CIE power
requirement:
130mA min.
220mA max
i-kp01 power
requirement:
30mA (normal/idle)
45mA (backlight low)
65mA (backlight high)
KEY-
KPZ01/KP01/K01
power requirement
35mA backlight OFF,
internal prox reader only.
65mA max backlight ON,
external prox reader

Table of Contents