Loading...
i-on40 Technical Specification
Page 27
connected
Battery charging
requirement:
270mA
Plug-on
Communicator power
requirement:
i-sd02, i-dig02:
20mA quiescent
50mA max
Plug-on
Communicator power
requirement
i-gsm02:
150mA quiescent
and max.
12V Aux output
voltage range:
9±0.5V to 13.8V
14.4V output voltage
range:
9±0.5V to 14.7V
Max p-to-p ripple
voltage:
0.5V
Standby Battery:
12V, 7Ah sealed lead
acid.
Max recharge time to
80% capacity:
Less than 72 hours.
‘Low battery’ fault at:
< 12V
Aux power output fault
at:
< 9V
Deep discharge
protection at:
9±0.5V
Serviceable
components:
Mains fuse: 250mA (T)
Standby time:
See “Power Availabillity”
on page 6.
Electromagnetic
Compatibility
Immunity
Conforms to EN50130-4.
Emissions
Conforms to EN61000-6-3.
Outputs
O/P 1 - 2
Voltage free, single pole relay
contacts rated 24VDC @ 1A.
O/P 3 - 4
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Plug-by O/Ps
1...12
Open collector transistor
+12VDC when inactive, 0V
when active, 50mA max.
LS
(loudspeaker)
Min impedance 16 Ohm,
current consumption from
12VAux = 280mA in alarm.
KEY-KPZ01
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active, 500mA max.
Fuses
The control unit has a replaceable T250mA mains
fuse.
Electrical Safety
Conforms to EN60950-1.
Other
If you wish to connect the i-on40 control unit to a
PC using either the Ethernet or the USB port then
make sure that the cables have the following
specifications:
Ethernet
Cat5e patch cable, RJ45 male
plugs at each end, suitable for
10/100Base-T.
USB
Mini-B plug for control unit end,
USB-A for PC end. Max length
3m.