P14 Technical Specifications*
Electrical Input
Nominal Voltage 230 Vac (user selectable to 220 Vac)
Online Voltage Range ±20% for nominal voltage at full load
Nominal Input Frequency 45–65 Hz, 50/60 Hz; auto-sensing
Input Protection Reset-able circuit breaker
Connection IEC-320-C14
Electrical Output
Power Levels 950W/1400 VA
Online Regulation -10%, +6% of nominal voltage
On Battery Voltage Regulation ±5% of nominal voltage; -10% after low battery warning
On Battery Frequency Regulation ±0.1 Hz of nominal frequency
Voltage Wave Shape Sine wave (during normal and battery operation)
Connections (6) IEC-320-C13
Indicators and Controls
Front Panel LEDs Power on, on battery, overload, and battery fault
Front Panel Buttons On/off and alarm silence/self-test
Communication Port
DB-9 female (UPS ships with communication cable); USB Interface Adapter is
optional
Battery
Battery Type Sealed, maintenance-free lead-acid; starved electrolyte
Battery Description (3) 12V, 9 Ah
Battery Recharge <3 hours to 90% capacity
Battery Runtime See Battery Runtimes table
Start-On-Battery Startup with UPS batteries in absence of utility power
General
Topology Line-interactive
Diagnostics 0.68
Dimensions and Weight See Model Guide
Network Transient Protector
In and out RJ-11 jack for telephone/modem protection or RJ-45 for 10BaseT network
cable; UL497A tested
Environmental and Safety
Operating Temperature 0°C to 40°C (32°F to 104°F) UL tested at 25°C (77°F)
Transit/Storage Temp. -15°C to 55°C (5°F to 131°F)
Heat Dissipation 189 BTU/hr, maximum
Audible Noise <45 dBA typical
Relative Humidity 5% to 95% noncondensing
Safety Markings UL, cUL, and CSA
Safety Conformance UL 1778, CAN/CSA C22.2, No. 107.1
EMC Markings FCC Class B; 230V models also CE (EN50091-2) and C-Tick
Surge Suppression ANSI C62.41 Category A (formerly IEEE 587)
Immunity IEC 801-2, -3, -4