battery capacity 55 Ah | 1270 kg |
---|---|
battery capacity 67 Ah | 1430 kg |
battery capacity 125 Ah | 2350 kg |
capacity | 40/36 kVA/kW |
---|---|
nominal input voltage | 220/380, 230/400, 240/415 VAC |
input voltage range | -15%, +10% from nominal at 100% load |
operating temperature | 0°C to +40°C, +45°C with 7, 5% derating |
---|---|
storage temperature | -15°C to +45°C |
altitude | < 1500 m |
dimensions | 519x1872x804 mm |
---|---|
weight UPS | 257 kg |
battery capacity 55 Ah | 1270 kg |
---|---|
battery capacity 67 Ah | 1430 kg |
battery capacity 125 Ah | 2350 kg |
capacity | 60/54 kVA/kW |
---|---|
nominal input voltage | 220/380, 230/400, 240/415 VAC |
input voltage range | -15%, +10% from nominal at 100% load |
operating temperature | 0°C to +40°C, +45°C with 7, 5% derating |
---|---|
storage temperature | -15°C to +45°C |
altitude | < 1500 m |
dimensions | 519x1872x804 mm |
---|---|
weight UPS | 313 kg |
battery capacity 55 Ah | 1270 kg |
---|---|
battery capacity 67 Ah | 1430 kg |
battery capacity 125 Ah | 2350 kg |
capacity | 80/72 kVA/kW |
---|---|
nominal input voltage | 220/380, 230/400, 240/415 VAC |
input voltage range | -15%, +10% from nominal at 100% load |
operating temperature | 0°C to +40°C, +45°C with 7, 5% derating |
---|---|
storage temperature | -15°C to +45°C |
altitude | < 1500 m |
dimensions | 519x1872x804 mm |
---|---|
weight UPS | 313 kg |
battery capacity 55 Ah | 1270 kg |
---|---|
battery capacity 67 Ah | 1430 kg |
battery capacity 125 Ah | 2350 kg |
capacity | 100/90 kVA/kW |
---|---|
nominal input voltage | 220/380, 230/400, 240/415 VAC |
input voltage range | -15%, +10% from nominal at 100% load |
operating temperature | 0°C to +40°C, +45°C with 7, 5% derating |
---|---|
storage temperature | -15°C to +45°C |
altitude | < 1500 m |
dimensions | 900x1872x804 mm |
---|---|
weight UPS | 480 kg |
battery capacity 55 Ah | 1270 kg |
---|---|
battery capacity 67 Ah | 1430 kg |
battery capacity 125 Ah | 2350 kg |
capacity | 120/108 kVA/kW |
---|---|
nominal input voltage | 220/380, 230/400, 240/415 VAC |
input voltage range | -15%, +10% from nominal at 100% load |
operating temperature | 0°C to +40°C, +45°C with 7, 5% derating |
---|---|
storage temperature | -15°C to +45°C |
altitude | < 1500 m |
dimensions | 900x1872x804 mm |
---|---|
weight UPS | 480/530 kg |
battery capacity 55 Ah | 1270 kg |
---|---|
battery capacity 67 Ah | 1430 kg |
battery capacity 125 Ah | 2350 kg |
capacity | 160/144 kVA/kW |
---|---|
nominal input voltage | 220/380, 230/400, 240/415 VAC |
input voltage range | -15%, +10% from nominal at 100% load |
operating temperature | 0°C to +40°C, +45°C with 7, 5% derating |
---|---|
storage temperature | -15°C to +45°C |
altitude | < 1500 m |
dimensions | 900x1872x804 mm |
---|---|
weight UPS | 530 kg |
Highlights essential safety precautions and warnings for UPS installation and operation.
Outlines environmental and physical requirements for the UPS installation site.
Details the process of inspecting and safely unpacking the UPS cabinet.
Describes the procedures for physically installing the UPS cabinet.
Outlines the process for initial startup and operational checks by authorized personnel.
Ensures all installation tasks, hardware, and cables are correctly completed.
Provides instructions for installing the UPS batteries according to manufacturer guidelines.
Explains the functions of the LCD display and pushbuttons on the UPS control panel.
Guides users on navigating the main menu and accessing system data.
Details how to control UPS functions like power module and charger status.
Explains how to interpret the status indicators (LEDs) for UPS operation.
Provides step-by-step instructions for operating a single UPS module.
Details the procedures for operating a parallel UPS system.
Highlights safety precautions essential for UPS maintenance and servicing.
Outlines routine preventive maintenance tasks for the UPS system.