5 Parameters
5.3 List of parameters
96 DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com
5.3 List of parameters
The abbreviations used in the parameter lists have the following meaning:
Figure 60: Parameter Access
PNU
Parameter number
ID Identification number of the parameter
RUN Access rights to the parameters during operation (RUN):
/ = Modification permissible,
- = Modification only possible in STOP
ro/rw
Parameter read and write permissions via a fieldbus connection (BUS):
ro = read only
rw = read and write
Value Parameter settings
Value ranges
Display values
WE
Default settings
Page Page in this manual with additional configuration and application examples
for the parameter
The first time the device is switched on, as well as any time
after restoring its default settings, only basic parameters P-01 to
P-14 will be shown. To access the extended parameter set,
enter 101 (= WE and P-37) for parameter P-14.
P-01
P-02
P-03
P-14 101
P-01
P-02
P-03
P-14
P-15
P-16
P-53