Step 4 - Start-up
POWERXL DM1 SERIES ADJUSTABLE FREQUENCY DRIVES PUB53696—August 2020 www.eaton.com
Table 6. Start-up wizard instructions (Cont.).
Description:
Motor nominal nameplate full load current. Find this value on the rating plate of the motor.
1410 min
230/400V 4.0/2.3A
50 Hz
–1
0.75 kW
cos
0.67
Voltage
Current
Motor Nom.
Speed
Motor PF
Frequency
P1.7
a
Motor nominal speed
ID 489
Minimum value:
300 rpm
Maximum value:
20,000 rpm
Default value:
MotorNomSpeedMFG
Description:
Motor nominal nameplate base speed. Find this value on the rating plate of the motor.
P1.8
a
Motor power factor
ID 490
Minimum value:
0.30
Maximum value:
1.00
Default value:
0.85
Description:
Motor nominal nameplate full load power factor. Find this value on the rating plate of the motor.
P1.9
a
Motor nominal voltage
ID 487
Minimum value:
180 V
Maximum value:
690 V
Default value:
487 V
Description:
Motor nominal nameplate base voltage. Find this value on the rating plate of the motor.
P1.10
a
Motor nominal frequency
ID 488
Minimum value:
8.00 Hz
Maximum value:
400.00 Hz
Default value:
MotorNomFreqMFG
Description:
Motor nominal nameplate base frequency. Find this value on the rating plate of the motor. This parameter sets the field weakening
point (P8.4) to the same value.
P1.3
b
Acceleration time 1
ID 103
Minimum value:
0.10 s
Maximum value:
3000.00 s
Default value:
20 .00 s
Description:
The time required for the output frequency to accelerate from zero frequency to maximum frequency (P1.2). When accelerating from
different frequency levels, the acceleration time will be a fraction of the total ramp time.
P1.4
b
Deceleration time 1
ID 104
Minimum value:
0.10 s
Maximum value:
3000.00 s
Default value:
20 .00 s
.