Loading...
End Suction Centrifugal
GS Series
Operating Instructions, Installation & Maintenance Manual
EBARA Pumps Americas Corporation

Questions and Answers

Summary

Introduction

Safety

Preparation and Training of Staff

Personnel involved in installation, operation, maintenance, and control must be properly trained.

Maintenance

No technical or structural changes permitted without prior approval; use genuine spare parts.

Transport and Storage

Specifications

Operating Limits

Installation

Installation Point

Install in an easily accessible place, close to water supply, with minimal height difference.

Lifting

Use straps at an angle less than 60 degrees, avoid motor/pump attachment points.

Cemented Base

Fix pump units on a stable, durable, rigid, permanent, and aligned cemented base.

Pipes

Ensure suction/delivery ducts don't transmit stress; fit check valves and air relief valves as needed.

Alignment

Check and adjust coupling alignment using shims to stay within specified tolerances.

Electrical System

Details on electrical system requirements, connection, and maintenance procedures.

Operation

Before Starting the Pump

Ensure pipes are flushed, pump spins freely, motor details are correct, and pump is primed.

Starting the Pump

Shut off delivery valve, open suction valve, briefly start/stop motor, then gradually open delivery valve.

Stopping the Pump

Gradually close the delivery valve before stopping the pump. Disconnect motor switch if power fails.

Maintenance

Daily Inspection

Monitor pressure, capacity, vibration, noise for malfunctions; keep a daily register.

Precautions During Operation

Avoid operating with closed delivery valve or excessive starts/stops to prevent pump damage.

Precautions During Storage

Insulate or drain pump to prevent freezing; perform test runs on spare pumps; prevent oxidation.

Replacing Parts

Replace worn parts like mechanical seals, bearings, and O-rings based on condition and replacement periods.

Troubleshooting

Table of common pump faults, causes, and measures to be taken for resolution.

Residual Risks

Consider risks like burns, entrapment, impacts during operation, maintenance, and transport; take safety measures.

Construction

Dismantling and Assembly

Repair and Warranty

EBARA GS Series Specifications

General IconGeneral
BrandEBARA
ModelGS Series
CategoryWater Pump
LanguageEnglish

Related product manuals