- 1 -
EBARA End Suction
Volute Pumps
GS/GSD Model
Instruction Manual
To installation personnel:
Be sure to issue the customer’s pump operation, maintenance, and inspection personnel with copies of
this manual.
CONTENTS
1
Warnings
.................................................. 2
3. Adjustment of gland packing
.......................
14
2
Safety cautions
........................................ 2
4. Replacement of gland packing
..................
14
3
Delivery checks
........................................ 6
5.
Cautions for operation ..........................
15
1. The pump and accessories..........................6
7
Maintenance
...............................................
15
2. Nameplate ...................................................6
1. Daily inspection......................................... 16
3. Lifting and carrying in/out.............................7
2. Prolonged stoppage and storage………... 17
4
Specifications
.......................................... 7
3. Replaceable parts ..................................... 17
5
Installation
................................................ 8
8
Troubleshooting
.................................... 19
1. Location .......................................................8
9
Structure
................................................ 22
2. Pipes ...........................................................9
1. External view and residual risks ............... 22
3. Alignment................................................... 10
2. Exploded view .......................................... 23
4. Electrical connection .................................. 11
3. Accessories .............................................. 24
5. Electrical maintenance .............................. 12
10
Disassembly and Assembly
.................. 25
6
Operation
................................................ 12
1. Disassembly ............................................. 25
1. Preparation for operation ........................... 12
2. Assembly .................................................. 31
2. Operation
Stopping ................................. 13
CAUTION
Thank you for choosing the EBARA GS/GSD Model End suction volute Pump. EBARA/Ebara Bombas
América do Sul Ltda.(EBAS) take every caution in manufacturing the product for safe use by the
customer. However, handling this pump in an inappropriate manner may reduce its functional capacity
and result in an accident.
This operation manual explains the proper procedures concerning the installation, operation, and
maintenance of the product. This manual should be read before conducting operation and
maintenance and inspections on this pump.
Installation personnel must provide copies of this manual to the customer’s pump operation,
maintenance and inspection personnel. Keep this manual in a safe place where it can be consulted at
any time.

Other manuals for EBARA GS

Questions and Answers

  • S
    Sarah MarshallSep 23, 2025
    Why EBARA Water Pump has low rotation speed?
    • M
      Michelle VargasSep 23, 2025
      If your EBARA Water Pump has a low rotation speed, it may be caused by low voltage (change the nominal voltage), poor Star/Delta commutation (correct the cabling), overloading (reduce the current), or a defective electrical connection (correct the electrical connections).
  • M
    Morgan TaylorAug 25, 2025
    Why is my EBARA Water Pump flow rate so low?
    • C
      Craig ColemanAug 25, 2025
      If your EBARA Water Pump has a low flow rate, several factors could be responsible. The direction of rotation might not be correct, so you should correct the electrical connections. There could be low voltage, requiring you to check the power supply. Also, check for blockages in the bottom valve or filter, and remove any foreign bodies. Air entering the system could also be the cause; in that case, check and repair the suction pipe and shaft seal. Leakage in the delivery pipe can also cause low flow; check and repair as needed. If none of these issues are present, the impeller might be worn, so check the impeller. Significant head losses in the system, high liquid temperature, or cavitation could also be the cause and require further review or expert advice.
  • I
    Isabel WaltonAug 25, 2025
    How to reduce vibration and noise in my EBARA GS?
    • K
      Kristin MasonAug 26, 2025
      Excessive vibration and noise in your EBARA Water Pump can be caused by several factors. A fault in the installation is possible, so check the installation. Damaged bearings could also be the source, requiring replacement. If the flow rate is too high or too low, adjust the delivery valve accordingly. An impeller blockage can also cause these issues, so remove any foreign bodies. Incorrect rotation direction can also lead to these problems; check and correct the connection. Friction in the rotation areas can also be a cause. Cavitation is another potential cause. Vibrations in the piping may also contribute to the noise and vibration.
  • A
    Alexandra GatesAug 27, 2025
    What causes my EBARA Water Pump motor to overheat and smell bad?
    • K
      Kyle PattonAug 27, 2025
      If your EBARA Water Pump motor is overheating and emitting smoke or a bad smell, high power surges could be the cause; correct the power surges. Another possibility is a blocked fan; release the fan. The voltage may also be wrong; change the motor for one with the appropriate voltage.
  • A
    Aaron CalhounAug 27, 2025
    Why does my EBARA GS Water Pump have no flow rate?
    • P
      phillipstracyAug 27, 2025
      If your EBARA Water Pump has no flow rate, it could be due to several reasons. The pump may not be turning, so check that the impeller is free. The delivery valve might be closed or half-closed, so open the valve. The suction head could also be too high for the pump, so check the project.
  • K
    Kiara MezaSep 15, 2025
    Why EBARA Water Pump shaft seal is leaking excessively?
    • A
      Angela RodgersSep 15, 2025
      Excessive water leakage from the shaft seal of your EBARA Water Pump may be due to defective fitting of the mechanical seal (fit it correctly), a damaged mechanical seal (replace the mechanical seal), overpressure in delivery (review the project), or a bent shaft (repair in specialist workshop).
  • N
    nathaniel35Sep 12, 2025
    What to do if EBARA Water Pump has no flow rate?
    • N
      nmcclureSep 12, 2025
      If your EBARA Water Pump has no flow rate, it could be because the pump does not turn (check that the impeller is free), the delivery valve is closed or half-closed (open the valve), or the suction head is too high for the pump (check the project).
  • R
    Ricky MaloneSep 14, 2025
    Why EBARA Water Pump stops abruptly after initial water flow?
    • J
      James RossSep 14, 2025
      If water comes out initially from your EBARA Water Pump and then stops abruptly, it may be because the pump has not been primed correctly (prime the pump correctly), air is entering the system (check and repair the suction pipe and shaft seal), there are air bubbles in the suction pipes (vent the pipes), or the suction head is too high for the pump (review the project).
  • R
    Roberto WernerSep 5, 2025
    Why my EBARA Water Pump motor will not start?
    • B
      brownfranciscoSep 5, 2025
      If the EBARA Water Pump motor won't start, possible causes include a faulty control panel (check all conditions), motor failure (repair the motor), power supply faults (check and repair), friction on the rotation shaft (rotate by hand and reassemble), or a clogged pump (remove foreign bodies).
  • T
    Tamara JonesSep 2, 2025
    What causes low rotation speed in my EBARA GS Water Pump?
    • B
      bcraigSep 3, 2025
      A low rotation speed in your EBARA Water Pump can be caused by several factors. Low voltage is a possibility, so change the nominal voltage. Poor Star/Delta commutation could also be the cause, so correct the cabling. Overloading can also reduce the rotation speed; reduce the current. Finally, a defective electrical connection might be the issue; correct the electrical connections.

Summary

Pump Safety and Warnings

Warning Grades and Cautions

Explanation of warning grades (Warning, Caution) and their meanings for safe operation.

General Safety Cautions

Essential safety precautions to prevent injury and equipment damage.

Pump Delivery and Specifications

Delivery Checks

Procedures for inspecting the pump and accessories upon delivery.

Nameplate Details

Understanding pump specifications and identifying 50Hz vs 60Hz differences.

Technical Specifications

Key technical data and standard specifications for the GS/GSD pump models.

Pump Installation Procedures

Installation Location

Guidelines for selecting an appropriate installation site for the pump.

Piping Requirements

Instructions for correct installation and arrangement of suction and delivery pipes.

Shaft Alignment

Procedures for aligning pump and motor shafts for proper operation.

Electrical Connections

Steps and precautions for connecting the pump's electrical power supply.

Electrical Maintenance

Guidance on maintaining the electrical components of the pump system.

Pump Operation and Maintenance

Operation Preparation

Essential steps to take before starting the pump for the first time.

Operation and Stopping

Safe procedures for starting, operating, and stopping the pump.

Gland Packing Adjustment

How to adjust gland packing for optimal performance and minimal leakage.

Gland Packing Replacement

When and how to replace gland packing due to wear or damage.

Operational Cautions

Important warnings and recommendations for safe and efficient pump operation.

Daily Inspection Routine

Routine checks to perform daily to ensure the pump is operating correctly.

Stoppage and Storage Procedures

Procedures for storing the pump during extended periods of non-use.

Replaceable Parts Guide

Identifying common parts that require periodic replacement.

Troubleshooting Guide

Pump Fault Diagnosis

Common pump faults, their causes, and recommended corrective actions.

Motor Fault Diagnosis

Troubleshooting common motor issues like starting problems, noise, and overheating.

Pump Structure and Service

External View and Risks

Identifying external parts of the pump and associated risks.

Exploded Component View

Detailed breakdown of pump components with identification numbers.

Included Accessories

List of standard accessories supplied with the pump.

Disassembly Guide

Step-by-step guide for taking the pump apart for maintenance or repair.

Assembly Guide

Step-by-step guide for reassembling the pump after maintenance or repair.

EBARA GS Specifications

General IconGeneral
TypeCentrifugal Pump
ModelGS
ApplicationWater supply, irrigation, industrial
MaterialCast iron, stainless steel
Liquid TemperatureUp to 90°C
Maximum Working Pressure10 bar
Motor TypeElectric
Speed2900 rpm