Instruction Manual
Request
Welcome to the EBARA submersible pump. EBARA fabricated the pump with special care for assuring
safe handling. Since, however, mal-operation of the pump may induce accident, correct use of the pump
referring to the instruction manual is requested.
The Instruction Manual shall be stored at a place allowing ready reference.
To the personnel of installation works
The Instruction Manual shall be handed to the user who conducts operation, maintenance, and
inspection of the pump.
Contents (page) (page)
Warning indication ....................................... 2
Maintenance .............................................. 12
Precautions of safety ................................... 3
1. Daily inspection ................................... 12
Introduction .................................................. 5
2. Regular inspection ............................... 12
1. Confirmation of pump and accessories 5
3. Precautions during stop-operation ...... 13
2. Confirmation of nameplate ..................... 5
4. When motor protection activated ..... 13
Product specification .................................... 6
5. Consumables ...................................... 13
Installation .................................................. 7
Troubleshooting ........................................ 14
1. Confirmation before installation ............. 7
Construction ................................................... 16
2. Installation .............................................. 7
1. Sectional view ........................................... 16
3. Electric wiring ......................................... 9
2. Accessory .................................................. 17
10 Disassembling and Assembling ................ 17
Operation ...................................................11
11 Limited Warranty ....................................... 17
1. Before starting ......................................11
12 Repair and after-sale service .................... 18
2. Test operation ......................................11
3. Operation .............................................11
This operational instruction manual
shall be handed to the user.
D8

Other manuals for EBARA DML

Questions and Answers

  • J
    Jason MooreAug 2, 2025
    How to troubleshoot if my EBARA DML Water Pump does not start?
    • A
      austinsmithAug 2, 2025
      If your EBARA Water Pump isn't starting, consider the following: * Remove any obstacles that may be preventing it from starting. * Inspect the connection section and the magnet switch. * Ensure the wiring is in the correct state. * Replace any inadequate fuses with adequate ones. * Replace inadequate magnets with adequate ones. * Repair or replace the level switch, motor, bearing, or mechanical seal if necessary. * Remove any foreign matter that may be obstructing the pump. * Request the electric power company for action.
  • I
    ithompsonAug 7, 2025
    What causes over current in my EBARA DML and how to fix it?
    • K
      Kim CobbAug 7, 2025
      If your EBARA Water Pump is experiencing an over current, here's what to investigate: * For large fluctuations of power source voltage, request the electric power company for action. * Inspect the connection section and the magnet switch. * Check the nameplate. * If operating the 50Hz pump at 60H, establish the correct rotational direction. * Narrow the opening of the gate valve, or if there is no gate valve, replace the pump with one having a lower head. * If the pump caches foreign matter, disassemble the pump to remove it. * If the motor bearing is broken, repair or replace the bearing.
  • J
    James ChavezAug 13, 2025
    Why is my EBARA Water Pump vibrating and generating large noise?
    • C
      Christian PattersonAug 13, 2025
      If your EBARA Water Pump is vibrating and generating a lot of noise, consider these potential issues: * If the pump is running in reverse, establish the correct rotational direction. * Disassemble the pump to remove any foreign matter. * If the piping is in resonance mode, modify the piping.
  • F
    Frederick BlackAug 17, 2025
    What to do if EBARA DML can be operated, but it stops after a while?
    • D
      Daniel WardAug 17, 2025
      If your EBARA Water Pump operates but stops after a while, it could be due to: * Prolonged dry operation causing the Auto-cut to function. In this case, raise the water level. * High liquid temperature triggering the Auto-cut. Try lowering the water level.
  • K
    Kelsey ButlerAug 22, 2025
    Why is the thermal protector actuated in my EBARA DML?
    • M
      Michael GordonAug 22, 2025
      If the thermal protector is actuated in your EBARA Water Pump, it might be due to: * High liquid temperature. In this case, lower the liquid temperature. * Long dry operation. Raise the stopping water level.
  • T
    Tina PerezOct 27, 2025
    What to do if my EBARA DML does not pump or has insufficient pumping rate?
    • J
      judy73Oct 27, 2025
      If your EBARA Water Pump isn't pumping or the pumping rate is insufficient, here's what you can check: * Ensure the pump isn't running in reverse. You may need to establish the correct rotational direction. * If the operating water level is low, it might be causing air suction. Try raising the water level or lowering the pump position. * Inspect the discharge pipe for any leaks and repair if necessary. * Remove any foreign matter that may be clogging the discharge pipe or adhered to the suction opening. * If foreign matter clogs the pump, disassemble the pump to remove it. * If you find a worn impeller, replace it. * Request the electric power company for action if there is a large voltage drop. * Check the nameplate if you are operating the 60Hz pump at 50Hz. * Review t...

Summary

Warning Indication

Precautions of Safety

Introduction

Confirmation of Pump and Accessories

Checks pump for transport damage and confirms all accessories are present.

Confirmation of Nameplate

Verifies pump specifications on the nameplate, especially frequency.

Product Specification

Installation

Confirmation Before Installation

Measures insulation resistance of the motor and cables before installation.

Installation

Covers safe handling, mounting, and wiring practices during installation.

Electric Wiring

Operation

Before Starting

Checks insulation resistance and water level before pump operation.

Test Operation

Guides on confirming rotational direction and checking pump performance during testing.

Operation

Starts pump operation after successful testing, advising against full gate valve opening.

Maintenance

Daily Inspection

Checks ammeter fluctuation and discharge rate for signs of foreign matter.

Regular Inspection

Covers monthly insulation resistance checks and bi-monthly oil replacement for mechanical seals.

Precautions During Stop-Operation

Advises on checking insulation resistance when the pump is idle underwater.

When Motor Protection is Activated

Instructs to check causes when motor protection is activated before restarting.

Consumables

Lists consumable parts and their replacement conditions or intervals.

Troubleshooting

Construction

Section Drawing: Typical Model

Displays sectional views of pump models with part number references.

Disassembly and Reassembly

Disassembly

Step-by-step guide for dismantling the pump, including removing specific parts.

Reassembly

Instructions for reassembling the pump, including adhesive application and rotation checks.

Limited Warranty

Repair and After-sale Service

EBARA DML Specifications