EasyManua.ls Logo

ebm-papst K3G400-HB41-01 - User Manual

ebm-papst K3G400-HB41-01
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operating instructions
K3G400-HB41-01
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND INFORMATION
11. SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1.1 Hazard levels for warnings
11.1 Hazard levels for warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualifications
11.2 Staff qualifications
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by suitably qualified, trained and
authorized technical staff.
Only authorized specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
11.3 Basic safety rules
The safety hazards associated with the device must be assessed again
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.
WARNING
To reduce the risk of fire, electric shock or injury to people, do
not use any replacement or add-on parts that have not been
approved by ebm-papst (e.g. parts manufactured with a 3D
printer).
21.4 Voltage
21.5 Safety and protective features
21.6 Electromagnetic radiation
21.7 Mechanical movement
21.8 Emissions
21.9 Hot surface
21.10 Transport
31.11 Storage
32. INTENDED USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Data according to Commission Regulation (EU) 327/2011
53.4 Technical description
63.5 Mounting data
63.6 Transport and storage conditions
63.7 Electromagnetic compatibility
64. CONNECTION AND STARTUP
64.1 Mechanical connection
74.2 Electrical connection
84.3 Connection in terminal box
94.4 Factory settings
104.5 Connection diagram
124.6 Checking connections
124.7 Switching on the device
124.8 Switching off the device
125. INTEGRATED PROTECTIVE FEATURES
136. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
136.1 Vibration testing
146.2 Cleaning
146.3 Safety inspection
146.4 Disposal
Item no. 56857-5-9970 · ENU · Change 260705 · Approved 2022-09-01 · Page 1 / 15
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Question and Answer IconNeed help?

Do you have a question about the ebm-papst K3G400-HB41-01 and is the answer not in the manual?

Overview

This document provides comprehensive operating instructions for the K3G400-HB41-01 device, a built-in fan designed for air conveyance. It emphasizes safety, proper usage, and maintenance to ensure optimal performance and longevity.

Function Description

The K3G400-HB41-01 is an integrated fan unit primarily designed for conveying air according to its technical specifications. It operates within power systems with grounded neutral (TN/TT), phase conductor grounding, or IT power systems, and is compatible with network quality characteristics as per EN 50160. The device is intended for stationary systems and is equipped with various protective features to ensure safe operation. These include thermal overload protection for the electronics and motor, line undervoltage/phase failure detection, and reverse polarity/locked-rotor protection. The fan incorporates an integrated EMC filter for compliance with electromagnetic compatibility limits, which may result in reactive currents in the supply line even when the motor is at a standstill. The device also features a status relay for monitoring operational status and error messages, and a control interface with SELV potential safely disconnected from the mains.

Usage Features

The device is designed for use in ambient air pressure between 800 mbar and 1050 mbar and within its permitted ambient temperature range. It must always be operated with all protective devices in place, including a fixed protective device and guard grill, to prevent injury from rotating parts. The fan is a built-in component and requires installation in a system capable of withstanding the mechanical and thermal stresses it generates throughout its service life. When connecting the device, it is crucial to ensure that the power supply matches the device's voltage and that only cables designed for the indicated current level are used. Special attention must be paid to the protective earth connection, which should have a cross-section equal to or greater than the phase conductor. For installations requiring residual current devices (RCDs), only AC/DC-sensitive devices (type B or B+) with a trip threshold of 300 mA and delayed tripping (super-resistant, characteristic K) are permissible. The device's control lines should be routed separately from the supply line with a clearance of more than 10 cm to prevent malfunctions. Water ingress into the terminal box must be prevented by routing cables in a U-shaped loop or by fitting a drip edge. The fan can be controlled via PWM or analog signals, with adjustable set values and direction of action (positive heating). It also supports RS-485 MODBUS-RTU for advanced control and monitoring. The device can be enabled or disabled via a digital input, which can also trigger a software reset.

Maintenance Features

Regular maintenance is crucial for the device's safe and trouble-free operation. This includes checking the device's electrical equipment at regular intervals and immediately replacing loose connections and defective cables. A safety inspection should be performed at least every 6 months, including a visual inspection of the contact protection cover, fastening of the cables, insulation of cables, and cable glands. The device should be cleaned regularly to prevent dirt deposits, which can cause vibration and shorten service life. Cleaning should be done with a soft cloth and mild cleaning agents, avoiding high-pressure cleaners, acids, alkalis, or solvent-based agents. If cleaning with compressed air, ensure it is dry and oil-free. Vibration testing is recommended every 6 months, measuring vibration severity on the motor's fastening diameter. If vibration levels exceed 3.5 mm/s, the impeller should be cleaned or replaced. The ball bearings are designed for a service life of 40,000 hours and do not require maintenance. The device is designed for easy disposal, with components made of steel, copper, aluminum, and plastic, which are generally recyclable. Specific guidelines for recycling and disposal of various materials, including ferrous and non-ferrous metals, insulating materials, cables, and electronic scrap, are provided. Any modifications, additions, or conversions to the device must be approved by ebm-papst to maintain safety and warranty validity.

ebm-papst K3G400-HB41-01 Specifications

General IconGeneral
TypeAxial fan
Voltage380-480 V
Power Consumption0.45 kW
AirflowMax. 2400 m³/h
Speed1400 rpm
Noise Level75 dB(A)
Motor technologyEC motor
Impeller diameter400 mm
Type of protectionIP54
Housing materialSteel

Related product manuals