Chengdu Ebyte Electronic Technology Co., Ltd E104-BT11 User Manual
Copyright ©2012–2020,Chengdu Ebyte Electronic Technology Co.,Ltd
Configure 16 byte of NetKey data
Return 16 byte of configured NetKey data
12 C0 00 11223344556677889900112233445566
12 40 00 11223344556677889900112233445566
1. This directive only applies to BT11-G;
2. The instruction does not support repeated settings;
3. Effective immediately, save after power off.
5.4.1.2 Read NetKey
Return 16 byte of configured NetKey data
12 40 01 11223344556677889900112233445566
1. This command reads the NetKey that has been set;
2. This instruction is only for BT11-G.
5.4.1.3 AppKey configuration
Configure 16 byte of AppKey data
Return 16 byte of configured AppKey data
12 C0 02 11223344556677889900112233445566
12 40 02 11223344556677889900112233445566
1. This directive only applies to BT11-G;
2. This command can only be used after adding Netkey, and only supports configuring one APPkey.
5.4.1.4 AppKey read
Configure 16 byte of AppKey data
Return 16 byte of configured AppKey data
12 40 03 11223344556677889900112233445566
1. This directive is only applicable to BT11-G;
2. This command reads the AppKey that has been set.