Ebyte E95-DTU - Factory Default Parameters

Ebyte E95-DTU
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co.,Ltd. E95-DTU(900SLxx-485) User Manual
Copyright ©2012–2022Chengdu Ebyte Electronic Technology Co.,Ltd.
2
1
0
WOR cycle
Only valid for mode 1;
Period T= (1+WOR)*500ms, the
maximum is 4000ms, and the minimum
is 500ms;
The longer the WOR monitoring interval
period, the lower the average power
consumption, but the greater the data
delay;
The sender and receiver must agree (very
important)
0
0
0
500ms
0
0
1
1000ms
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
07H
Writ
e
CR
YPT
_H
Key high byte (default 0)
write only, read returns 0;
Used for encryption to avoid interception
of air wireless data by similar radio
stations;
The radio will use these two bytes as a
calculation factor to transform and
encrypt the air wireless signal.
08H
Writ
e
CR
YPT
_L
key low byte (default 0)
80H
86H
Rea
d
PID
PID Product Information 7 bytes
PID Product Information 7 bytes
6.3 Factory default parameters
Mode
Factory default parameter valueC0 00 00 62 00 00
Radio model
Frequency
Addres
s
Channel
Air rate
baud rate
Serial
format
transmit
power
E95-DTU(900SLxx-48
5)
850.125M
Hz
0x000
0
0x17
2.4kbps
9600
8N1
22dBm (low
power)
30dBm (high
power)