Page 12 of 20
After the module groups have a sequence selected, a ash pattern rate can be chosen. The default rates are as follows in TABLE 10.
Level Mode Default Flash Rate by Module Group - Synchronized
Module Group L1 L2 L3
Front Quad 75 FPM Quad 75 FPM Cycle
Rear Quad 75 FPM Quad 75 FPM Cycle
L1 + L2 L1 + L3 L2 + L3 L1 + L2 + L3
Front Quad 75 FPM Cycle Cycle Cycle
Rear Quad 75 FPM Left/Right Cycle Cycle
TABLE 10
To change a Module group’s ash pattern rate selection:
1. Power-up the lightbar and apply +power to a single level mode (see Table 2) in the 16 conductor cable.
2. Momentarily touch the BLK/RED Pattern select wire and the appropriate Module group wire, shown in Table 11, to +power to cycle through
the ash pattern rates shown in shown in Table 12. Hold the wires to +power for more than 4 seconds to return to the factory default
setting.
Module Group Flash Rate Wires - Synchronized
Function Wire Color Module Group
GRN/WHT Front
BLU/BLK Rear
TABLE 11
Module Group Flash Patterns -
Unsynchronized
Order Flash Pattern
1 Double 75 FPM
2 Triple 75 FPM
3 Quad 75 FPM
4 Quint 75 FPM
5 Triple Pop 75 FPM
6 Quad Pop 75 FPM
7 Single 150 FPM
8 Double 150 FPM
9 Triple 150 FPM
10 Quad 150 FPM
11 Quint 150 FPM
12 Triple Pop 150 FPM
13 Quad Pop 150 FPM
14 Single 375 FPM
15 NFPA Quad 77 FPM
16 Cycle Flash
TABLE 12