MAINTENANCE PB-755S H/T
32 X7531125705
© 11/19 ECHO Incorporated
Air Filter
Level 1.
1. Close choke (COLD START [ ]
position). This prevents dirt from
entering the carburetor throat
when the air filter is removed.
Brush accumulated dirt from air
cleaner area.
2. Remove air filter cover (A). Brush
dirt from inside cover.
3. Remove air filter (B) and lightly
brush debris from filter. Replace
filter if it is damaged, fuel
soaked, very dirty, or the rubber
sealing edges are deformed.
4. If filter can be reused, be certain it:
Fits tightly in the air filter cavity
Is installed with the original side out
5. Install air filter cover.
Fuel Filter
Level 1.
Fuel is VERY flammable. Use extreme care when mixing, storing
or handling, or serious personal injury may result.
1. Use a clean rag to remove loose dirt
from around fuel cap and empty fuel
tank.
Parts Required: TUNE UP KIT
Parts Required: TUNE UP KIT.
A
B