MAINTENANCE PB-8010 H/T
36 X7501200001
© 11/2018 ECHO Inc.
Air Filter
Level 1.
1. Close choke (COLD START position). This prevents dirt from entering
the carburetor throat when the air filter is removed. Brush accumulated
dirt from air cleaner area.
2. Remove air filter cover, foam pre-filter, and air filter. Brush dirt from
inside cover.
Foam Pre-Filter:
Clean foam pre- filter (A) in
water/detergent solution and
rinse with clean water.
Wrap the foam pre-filter in a
clean, dry cloth and squeeze
(do not wring) dry. Allow to dry
completely before reuse. Do
not oil.
Air Filter:
Lightly brush debris from air
filter (B).
Replace filter if it is damaged,
very dirty, or the rubber
sealing edges are deformed.
If filter can be reused, be
certain it fits tightly in the air
filter cavity, and is installed with the original side out.
3. Assemble components in reverse order.
Parts Required: TUNE UP KIT.