45
XOVER_TYPE
<Zone=ZA:ZD>
LP/HP
Sets the current CROSSOVER FILTER TYPE (LP or HP) for the specified
output zone
XOVER_FREQUENCY
<Zone=ZA:ZD>
<Frequency=Hz>
Sets the current CROSSOVER FILTER FREQUENCY (Hz) for the
specified output zone
TYPE
PARAM1
PARAM2
PARAM3
PARAM4
DESCRIPCIÓN
DATA
INFO_MODEL
<DeviceModel>
Shows the Device model name
INFO_VERSION
<FirmwareVersion>
Shows the current Firmware Version
AUTOLOAD_PRESET1
ON/OFF
Shows the current AUTOLOAD_PRESET1 at Startup function
PRESET_NUMBER
<Preset=P1:P20>
<Preset=T1:T6>
Shows the current PRESET number (active preset)
PRESET_NAME
<Preset=P1:P20>
<Preset=T1:T6>
“<Name>”
Shows a certain PRESET (from P1 to P20) or TEMPLATE (from T1
to T6) name
PRESET_DONE
<Preset=P1:P20>
<Preset=T1:T6>
Shows that the last SET LOAD_PRESET or SET PRESET_NUMBER
command has been processed: the preset is loaded and active
REMOTE_MODE
<Remote=R1:R4>
<RemoteMode>
Shows the working mode for a certain REMOTE port (from R1 to
R4)
REMOTE_INPUTS
<Remote=R1:R4>
<Inputs=I1:I5>
Shows the list of inputs affected by the working mode of a certain
REMOTE port (from R1 to R4)
REMOTE_ZONES
<Remote=R1:R4>
<Zones=ZA:ZD>
Shows the list of outputs affected by the working mode of a
certain REMOTE port (from R1 to R4)
DISPLAY_MODE
<DisplayMode>
Shows the current DISPLAY MODE
LCD_CONTRAST
<Contrast=0:100>
Shows the current DISPLAY CONTRAST level
EXT_MUTE_ZONES
<Zones=ZA:ZD>
Shows the list of outputs to be muted by an external contact
closure, connected to the MUTE port
IN_LABEL
<Input=I1:I5>
“<Label>”
Shows the current LABEL (name) for the specified INPUT
IN_STEREO
<Input=I4:I5>
ON/OFF
Shows the current STEREO link status (ON or OFF) for INPUTs 4
and 5

Other manuals for Ecler CA120