EasyManua.ls Logo

Ecler CA120 - Page 46

Ecler CA120
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
IN_MUTE
<Input=I1:I5>
ON/OFF
Shows the current MUTE status (ON or OFF) for the specified
INPUT
IN_VOL
<Input=I1:I5>
<Volume=0:99>
Shows the current VOLUME for the specified INPUT (general input
volume, affecting all the post processing)
IN_BASS
<Input=I1:I5>
<Gain=dBx10>
Shows the current BASS tone LEVEL for the specified INPUT
IN_MID
<Input=I1:I5>
<Gain=dBx10>
Shows the current MIDDLE tone LEVEL for the specified INPUT
IN_TREBLE
<Input=I1:I5>
<Gain=dBx10>
Shows the current TREBLE tone LEVEL for the specified INPUT
HPF_ACTIVE
<Input=I4:I5>
ON/OFF
Shows the current HIGH PASS FILTER status (ON or OFF) for the
specified INPUT
HPF_FREQUENCY
<Input=I4:I5>
<Frequency=Hz>
Shows the current HIGH PASS FILTER frequency (Hz) for the
specified INPUT
FBS_ACTIVE
<Input=I4:I5>
ON/OFF
Shows the current FEEDBACK SUPPRESSOR feature status (ON
or OFF) for the specified INPUT
GATE_ACTIVE
<Input=I4:I5>
ON/OFF
Showss the current NOISE GATE status (ON or OFF) for the
specified INPUT
GATE_THRESHOLD
<Input=I4:I5>
<Threshold=dBx10>
Shows the current NOISE GATE THRESHOLD LEVEL (dBx10) for
the specified INPUT
GATE_DEPTH
<Input=I4:I5>
<Depth=dBx10>
Shows the current NOISE GATE DEPTH (attenuation when gate is
closed, dBx10) for the specified INPUT
GATE_ATTACK
<Input=I4:I5>
<AttackTime=ms>
Shows the current NOISE GATE ATTACK TIME (milliseconds x10)
for the specified INPUT
GATE_HOLD
<Input=I4:I5>
<HoldTime=ms>
Shows the current NOISE GATE HOLD TIME (milliseconds x10) for
the specified INPUT
GATE_RELEASE
<Input=I4:I5>
<ReleaseTime=ms>
Shows the current NOISE GATE RELEASE TIME (milliseconds x10)
for the specified INPUT
TALKOVER_ACTIVE
<Input=I4:I5>
ON/OFF
Shows the current TALKOVER status (ON or OFF) for the specified
INPUT
TALKOVER_MODE
<Input=I4:I5>
PAGER/DUCKER
Shows the TALKOVER function working mode (PAGER or
DUCKER) for the specified INPUT
TALKOVER_PRIORITY
<Input=I4:I5>
LOW/HIGH
Shows the current TALKOVER PRIORITY level (LOW or HIGH) for
the specified INPUT

Other manuals for Ecler CA120

Related product manuals