Possible causes of trouble
Faulty thermostat / room temperature
sensor
Wrong setting place of temperature
sensor
Shorted or open capacitor
Faulty magnetic contactor for
compressor
Faulty magnetic contactor for fan
Shorted or grounded compressor
Shorted or grounded fan motor
Compressor will not start but fans run
Compressor and condenser (outdoor)
fan will not start
Evaporator (indoor) fan will not start
Condenser (Outdoor) fan will not start
Unit runs, but shortly stops
Compressor short-cycles due to
overload
High discharge pressure
Low discharge pressure
High suction pressure
Low suction pressure
Unit runs continuously but insufficient
cooling
Too cool
Horizontal louver can not revolve ☆ ☆ ☆
Inspect connections - tighten
Test circuits with tester
Test continuity of safety device
Test continuity of thermostat / sensor & wiring
Place the temperature sensor at the central of the air
inlet grille
Check control circuit with tester
Check capacitor with tester
Test continuity of coil & contacts
Test continuity of coil & contacts
Replace the stepping motor
Check resistance with multimeter
Check resistance with multimeter