63
Dirty stove.
Too intensive use.
A005
Minimum NTC temperature.
Badly planned installation in terms of space.
Boiler working at low power levels.
Disconnected NTC.
A006 Maximum NTC temperature.
Air in the circuit.
Little dissipation of the energy generated.
Too heavily used.
Shortcut in NTC.
A007 Minimum water pressure.
Filling the heating circuit.
Disconnected Pressure switch.
Broken Pressure switch.
A008 Maximum water pressure.
Lowering operating pressure between 1.2 and 1.5
bar.
Installing a bigger expansion vessel.
Air in the circuit.
A009 Minimum room temperature.
Low temperature in the room.
Disabling the room sensor.
Lowering operating temperature.
A010 Maximum room temperature.
Too much temperature in the room.
Disabling the room sensor.
Increasing operating temperature.
A011
Minimum CPU Temperature.
CPU Temperature below the minimum.
A012 Maximum CPU Temperature.
Dirty stove.
Dirty or broken convector.
Inadequate installation of the gas output pipe.
A013
Motor currents below the minimum.
Reviewing motor connections.
A014
Motor currents above the maximum.
Reviewing motor short circuits.
A015 Depression air level too low.
Minimum depression operating conditions.
Dirty stove.
Dirty exhaust pipe.
Housing door or ash box incorrectly closed.
Cleaning outlet left open.
A016 Maximum gas temperature alert
It has reached the gas output safety.
Temperature and the pellet will drop.
A017 Maximum NTC temperature alert.
It reduces fuel drop due to excess temperature in
convection chamber or water flow.
A018
El extractor se pone al 100% y no alcanza la
depresión mínima de trabajo de forma
continuada.
Stove/heater dirty.
Need to perform maintenance work.
A019 Extractor de la salida de gases al 100%
Stove/heater dirty.
Need to perform maintenance work.
A020
Probes error
Possible sensor change.
A021
Minimum temperature in probe for outside
temperature. (OPTIONAL, check availability).
Temperature below -25°C.
A022
Maximum temperature in probe for outside
temperature. (OPTIONAL, check availability).
Temperature above 55°C.
A023
Minimum temperature in probe for return
temperature.
Installation of boiler badly measured.
Boiler working to low levels of power.
Disconnected NTC.
NTC badly placed.
A024
Maximum temperature in probe for return
temperature
Air in the circuit.
Little dissipation of the energy generated.
Too heavily used.
Shortcut in NTC.