64
Minimum temperature in “temperature 1 probe”,
used to monitor the sanitary hot water tank.
• Installation of boiler badly measured.
• Boiler working to low levels of power.
• Disconnected NTC.
•
A026
Maximum temperature in “temperature 1
probe”, used to monitor the hot sanitary water
tank.
• Little dissipation of the energy generated.
• Too heavily used.
•
A027
Minimum temperature in “temperature 2 probe”,
used to monitor the hot sanitary water tank.
• Installation of boiler badly measured.
• Boiler working to low levels of power.
• Disconnected NTC.
•
A028
Maximum temperature in
probe”, used to monitor the hot sanitary water
tank.
• Little dissipation of the energy generated.
• Too heavily used.
•
A029
Minimum temperature in “temperature 1 probe”,
used to monitor the buffer tank.
• Installation of boiler badly measured.
• Boiler working to low levels of power.
• Disconnected NTC.
•
A030
Maximum temperature in “temperature 1
probe”, used to monitor the buffer tank.
• Little dissipation of the energy generated.
• Too heavily used.
•
A031
Minimum temperature in “temperature 2 probe”,
used to monitor the buffer tank.
• Installation of boiler badly measured.
• Boiler working to low levels of power.
• Disconnected NTC.
•
A032
Maximum temperature in “temperature 2
probe”, used to monitor the buffer tank.
• Little dissipation of the energy generated.
• Too heavily used.
•
A033 burning pot open during cleaning phase.
Burning pot base poorly closed.
• Sensor dirty or broken.
• Engine broken.
• Cable or connector disconnected
Burning pot open during hardware test.
• Open or badly closed basket base.
• Sensor dirty or broken.
• Engine broken.
• Cable or connector disconnected.
A035 Burning pot open during operation.
• Open or badly closed burning pot base.
• Sensor dirty or broken.
• Engine broken.
• Wiring or connector disconnected or loose.
A036 Ashtray drawer open during hardware test.
• Full ashtray drawer, perform maintenance.
• Defective sensor.
• Defective Periphery.
• Wiring or connector disconnected or loose.
A037 Ashtray drawer open during operation.
• Ashtray drawer full, perform maintenance.
• Defective sensor.
• Defective Periphery.
• Wiring or connector disconnected or loose.
A038
Ashtray drawer open during operation (machine
off).
• Full ashtray drawer, perform maintenance.
• Defective sensor.
• Defective Periphery.
• Wiring or connector disconnected or loose.