EasyManua.ls Logo

Ecotec Amalfi - 3. Operating Your Pellet Fire; 3.1 Control Panel Description; 3.2 Stove Startup Procedure; 3.7 Chronothermostat Setup

Ecotec Amalfi
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
3. Operating your Pellet Fire
3.1 Description of the Controls
3.2 Switching on the Stove
1. Before switching the stove on, proceed as follows:
2. Plug in the power lead.
3. Put the switch at the back of the stove in position 1.
4. Check that the plant is connected to the ue.
5. Make sure that the hydraulic plant has been installed correctly by a technician and that
the boiler has been lled with water and bled correctly as described in chapter 2.9.3 of the
Installation Section at the back of this manual.
6. Fill the tank with 6-mm pellets as described in “Figure 18.” on page 23.
7. Load the screw as described in chapter “3.4 Priming of the Screw (Auger)” on page 10.
8. Press key P3 for 3 seconds.
At this point the thermostove will carry out the ignition phase. The following messages will appear on
the screen:
ON
LOAD PELLET
WAIT FOR FLAME
FLAME PRESENT
WORK
During the working phase, you must check the following settings:
POWER SETTING as described in chapter 3.10.1 on page 14.
ROOM TEMPERATURE SETTING as described in chapter 3.11.1 on page 14.
BOILER WATER TEMPERATURE SETTING as described in chapter 3.12 on page 15.
3.3 Operating Precautions
In case of faulty operation turn the stove off pressing button no. 3.
Do not manually load the re pot with pellets.
Any build up of unburned pellets inside the re pot after repeatedly trying to light the
stove, must be removed before further attempts.
Do not use any fuels other than wood pellets.
Should the ignition system be faulty, do not attempt to light the stove using ammable
materials.
20°C
10:00 20°C
OFF
P1 : Turns heat level down
P2 : Turns heat level up
P3 : Turns ire on-off
P4 : Turns thermostat down
P5 : Turns thermostat up
P6 : Decrease water temperature
P7 : Increase water temperature
Figure 2.

Table of Contents