ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
47
Idle current consumption of the charger SSI-series
Model 12 V 24 V 48 V
SSI100 approx. 0,5 A approx. 0,25 A approx. 0,12 A
SSI150 approx. 0,65 A approx. 0,32 A approx. 0,16 A
SSI200 approx. 0,8 A approx. 0,4 A approx. 0,2 A
SSI250 approx. 1,0 A approx. 0,5 A approx. 0,25 A
SSI300 approx. 1,2 A approx. 0,6 A approx. 0,3 A
Power of the AC-charger CSI-series
Model charging current
CSI34, CSI54, CSI104, 5 A
CSI32, CSI52, CSI102, CSI154, CSI204, CSI254, CSI304, 10 A
CSI152, CSI202, CSI252, CSI302, 20 A
Power of the AC-charger SSI-series
Model charging current
all 24 V models (SSI104, SSI154, SSI204, SSI254, SSI304) 10 A
all 12 V models (SSI102, SSI152, SSI202, SSI252, SSI302) 20 A
Efficiency range*
system voltage CSI-series SSI-series
12 V 86 % – 90 % 88 % – 92 %
24 V 87 % – 91 % 89 % – 93 %
48 V 88 % – 92 % 90 % – 94 %
* Actual efficiencies depend on the type of consumer and load.
For example, the inverter typically has the highest efficiency at a load of approx. 70 %.