ECTIVE
®
SINUS/SINE INVERTER – CSI-/SSI-SERIES
]
55
decreasing current ensures that the terminal voltage does not become too high during
the complete charging process.
FLOAT (charge maintenance): The battery status remains permanently at 13,8 V*
without overcharging or damaging the battery. The voltage is permanently controlled in
this mode. If the voltage decreases to a predefined level, the battery is charged through
a pulse charge until reaching again 100%, so the charge status remains permanently
between 95% and 100%. This charging-cycle is repeated appropriately and influences
the lifetime of the battery in a positive way.
* All voltage values refer to 12 V. For 24 V: double value, for 48 V: quadruple value.