3-1
Chapter 3: Installing the Switch
Selecting a Site
This unit can be mounted in a standard 19-inch equipment rack or on a flat surface.
Be sure to follow the guidelines below when choosing a location.
The site should:
- restrict access to authorized service personnel in accordance with IEC 60950-1.
A restricted access location is one where access is secure and limited to service
personnel who have a special key, or other means of security.
- be at the center of all the devices you want to link and near a power outlet.
- be able to maintain its temperature within 0 to 45 °C (32 to 113 °F) and its
humidity within 10% to 90%, non-condensing
- provide adequate space (approximately five centimeters or two inches) on all
sides for proper air flow
- be accessible for installing, cabling and maintaining the devices
- allow the status LEDs to be clearly visible
Make sure twisted-pair cable is always routed away from power lines, fluorescent
lighting fixtures and other sources of electrical interference, such as radios and
transmitters.
Make sure a separate grounded power outlet that provides 100 to 240 VAC, 50 to
60 Hz is within 2.44 m (8 feet) of the unit and is powered from an independent
circuit breaker. As with any equipment, using a filter or surge suppressor is
recommended.
Ethernet Cabling
To ensure proper operation when installing the switches into a network, make sure
that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T
operation. Check the following criteria against the current installation of your
network:
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables
with RJ-45 connectors; Category 3 or better for 10BASE-T, Category 5 or better
for 100BASE-TX, and Category 5 or better for 1000BASE-T.
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic fields
from data based network wiring
Safe connections with no damaged cables, connectors or shields

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ES3528MF-PoE and is the answer not in the manual?

Edge-Core ES3528MF-PoE Specifications

General IconGeneral
BrandEdge-Core
ModelES3528MF-PoE
CategoryNetwork Router
LanguageEnglish

Related product manuals