Unit will not Dry or Drying Insufficient (E37, E38, E3A)
Unit will not Dry or Drying
Insufficient (E37, E38, E3A)
Is drum rotating?
Check water inlet value (E10)
Check overload protectors
attached to heater to see if
tripped
Check all wires connected properly
to drying heater assembly.
Check the dryer heater
Check the Fan Flange and
capacitor. Replace if failed.
Check the Condenser Assembly
Replace the PCB's
If not, refer to ‘Drum Will Not Rotate’ section.
Check cold water valve and drying water inlet valve.
Manually reset overload protectors (2) if tripped.
(see images above: remove red / black connectors and press reset buttons if tripped)
Check resistance: Normal resistance is less than 5mΩ
Normal open circuit temperature: 165 +/- 5
(329 +/- 9 F)
Check wires to all temperature
sensors, heaters, fan flange,
and PCBs. Replace the
harness if failure found.
Check the temperature sensor table on next page.
The resistance should be in
range from 8 to 15Ω.
The resistance of main coil (blue and black
wires) should be in range from 80 to 110Ω.
The resistance of vice coil (blue and brown
wires) should be in range from 90 to 120Ω.
The capacitor should be
in range 2.5uf +/- 5%.
Check the Condenser assembly for lint accumulation. Clean if
there is lint blockage Condenser assembly.