© Edwards Limited 2008. All rights reserved. Page 3
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical Data
A386-11-880 Issue E
2Technical Data
2.1 Mechanical data
2.2 Performance
2.3 Operating and storage conditions
2.4 Construction materials
Figure 2 - Dimensions (mm) (CDP Exhaust-Silencer shown)
Dimensions See Figure 2
Mass 5.5 kg
Inlet connection NW40
Outlet connection NW40
Maximum throughput 80 m
3
h
-1
Maximum back-pressure 3 psig (at maximum throughput)
Exhaust gas temperature range 5 to 150 ºC
Exhaust pulse attenuation 30 dB(A)
Leak tightness better than 1 x 10
-5
mbar.ls
-1
(1 x 10
-3
Pa.ls
-1
) helium
Ambient temperature range (operation) 5 to 40 ºC
Ambient temperature range (storage) -30 to 50 ºC
Maximum ambient humidity (operation) 90% RH
Maximum ambient humidity (storage) 97% RH (non-condensing)
Silencer body Stainless steel, ISI grade 304L
‘O’ rings Fluoroelastomer