7.4.6 Outlet mist-filter (clean applications)
The outlet mist-filter (see Figure 8, item 3) collects the oil contained in the oil-mist forming part of the discharge
gases. You can monitor the level of oil trapped in the filter, through a sight-glass. This mist-filter must only be used
for clean applications. You can return the trapped oil to your pump using the oil return kit. The mist-filter is supplied
with two ISO40 ‘C’ clamps, ISO40 elbow, two 40 mm co-seals, bolts, washers, mounting bracket and studs.
7.4.7 External oil filter
The external oil filter (see Figure 8, item 2) is a free-standing filter. You can choose between two types of oil-filter.
The ‘A’ series uses an activated earth cartridge which provides chemical cleaning of the oil by removing acidic and
other aggressive contaminants. The ‘M’ series uses a pleated paper cartridge which does not provide chemical
filtering but removes abrasive particles down to 0.5 microns. You must check that the external oil filter you choose
is suitable for your application.
7.4.8 Solenoid-operated gas-ballast control valve
The solenoid-operated gas-ballast control valve (see Figure 8, item 5) gives you automatic or remote control of gas-
ballast. You can connect the valve to shut off gas-ballast when the pump is switched off and so prevent air from
returning to the system.
7.4.9 Thermostatic control valve
The thermostatic control valve (see Figure 8, item 6) promotes rapid pump warm-up and ensures optimum running
temperature by controlling cooling-water flow rate. This reduces water usage and running costs and significantly
improves vapour pumping performance.
Product Item Number
MF300 Mist Filter A462-04-000
Clean Application Oil Return Kit A500-05-000
Product Item Number
EOF300A External Oil Filter A500-03-000
Activated Earth Element for EOF300A A223-04-033
EOF300M External Oil Filter A500-23-000
Mechanical Filter-element for EOF300M A223-04-042
EOF300A and M Connection Kit A364-01-020
Product Item Number
EBV300D Solenoid-Operated Gas-Ballast A500-17-930
Control Valve for E2M175 and E2M275
Product Item Number
TCV300 Thermostatic Control Valve A500-01-000

Table of Contents

Other manuals for Edwards E2M275

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards E2M275 and is the answer not in the manual?

Edwards E2M275 Specifications

General IconGeneral
BrandEdwards
ModelE2M275
CategoryWater Pump
LanguageEnglish

Related product manuals