3.4 Lubricaon data
Note:
Manufacturers Material Safety Data Sheets for the oils specied below are available
upon request.
Table 4
Lubricaon data
Hydrocarbon pumps:
Recommended oil* Ultragrade 19
Maximum oil capacity 1.32 litres
PFPE - prepared EM pumps:
Recommended oil* Krytox 1506 or Fomblin 06/6
Maximum oil capacity 1.32 litres
* To operate the pump when the ambient temperature is outside the range specied in
Operang and storage condions on page 12, or to opmise pump performance when
processing condensable vapours, a dierent oil may be used.
3.5 Electrical data
Refer to Table: Electrical data: three-phase motors on page 15 and Table: Electrical data:
single-phase motors on page 15. For motor current informaon please refer to the
motor rang plate. The motor start-up current is drawn for less than one second, so
me-lag fuses must be used to prevent unnecessary fuse failure when the pump starts.
Fuses should be to EN60269 Performance on page 12. If using the pump at temperatures
lower than 13 °C, the start-up current will be drawn for longer; this may cause the motor
thermal overload device to open.
Table 5
Electrical data: three-phase motors
Pump item number Voltage (V) Frequency (Hz)
A37333940 380/400 and 230/460 50/60
A37333934 200 and 200/380 50/60
A37343940 380/400 and 230/460 50/60
A37343934 200 and 200/380 50/60
Motor output rang (connuous)
50 Hz operaon 0.75 kW
60 Hz operaon 0.90 kW
Table 6
Electrical data: single-phase motors
Pump item number Voltage (V) Frequency (Hz)
A37315903
A37316903, A37415903
220-240
230-240
50
60
A37315981, A37415981 115
230
60
60
A37315904, A37415904 100 50
Page 15
A37310880_V - Technical data