Edwards iGX100MTi User Manual

Edwards iGX100MTi
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A546–00–880
Issue C Original
Instruction Manual
iGX Dry Pumping Systems
Description Description
iGX100L 200 V – 230 V 50/60 Hz A546-10-958
iGX100L 380 V – 460 V 50/60 Hz A546-10-959
iGX100L 200 V – 230 V 50/60 Hz SS A548-10-958
iGX100L 380 V – 460 V 50/60 Hz SS A548-10-959
iGX600L 200 V – 230 V 50/60 Hz A546-30-958
iGX600L 380 V – 460 V 50/60 Hz A546-30-959
iGX600L 200 V – 230 V 50/60 Hz SS A548-30-958
iGX600L 380 V – 460 V 50/60 Hz SS A548-30-959
iGX100N 200 V – 230 V 50/60 Hz A546-11-958
iGX100N 380 V – 460 V 50/60 Hz A546-11-959
iGX100N 200 V – 230 V 50/60 Hz SS A548-11-958
iGX600N 200 V – 230 V 50/60 Hz A546-31-958
iGX600N 380 V – 460 V 50/60 Hz A546-31-959
Description Description
iGX1000N 200 V – 230 V 50 Hz A546-81-958
iGX1000N 380 V – 460 V 50 Hz A546-81-959
iGX1000N 200 V – 230 V 50/60 Hz SS A548-81-958
iGX100M 200 V – 230 V 50/60 Hz A546-12-958
iGX100M 380 V – 460 V 50/60 Hz A546-12-959
iGX100M 200 V – 230 V 50/60 Hz SS A548-12-958
iGX100MTi 200 V – 230 V 50/60 Hz A546-48-958
iGX100MTi 380 V – 460 V 50/60 Hz A546-48-959
iGX100MTi 200 V – 230 V 50/60 Hz SS A548-48-958
iGX600M 200 V – 230 V 50/60 Hz A546-32-958
iGX600M 380 V – 460 V 50/60 Hz A546-32-959
iGX600M 200 V – 230 V 50/60 Hz SS A548-32-958

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Edwards iGX100MTi and is the answer not in the manual?

Edwards iGX100MTi Specifications

General IconGeneral
BrandEdwards
ModeliGX100MTi
CategoryLaboratory Equipment
LanguageEnglish

Summary

3 Installation

3.1 Locate the dry pumping system

Instructions for positioning the iGX system in its operating location, including lifting and securing.

3.3 Connect the iGX system to your vacuum/exhaust system and interstage connection (if fitted)

Guidance on connecting the iGX system to vacuum and exhaust pipelines, including pressure rating and flexible pipelines.

3.5.1 Flammable/pyrophoric materials

Safety instructions and precautions for handling flammable or pyrophoric materials with the iGX system.

3.6 Leak-test the iGX system

Procedure for leak testing the iGX system after installation to prevent hazardous substance leakage.

3.7 Connect the electrical supply

Instructions for connecting the iGX system to the electrical supply, including safety warnings and earth connections.

3.9 Connect to your emergency stop circuit

Instructions for connecting the iGX system to an emergency stop facility and the EMO connector.

3.10 Connect the cooling-water hoses

Steps for connecting cooling-water hoses to the iGX system, emphasizing safety during electrical installation.

3.12 Commission the iGX system

Procedure for commissioning the iGX system, including checking power, supplies, and starting the pump.

3.13 Install additional safety equipment

Guidance on installing extra safety equipment, particularly for nitrogen flow measurement and system shutdown on failure.

4 OPERATION

4.1 Start-up

Steps to safely start the iGX system, including checking supplies and using controls.

4.6 Emergency stop

Instructions for using the emergency stop switch and related controls for immediate shutdown.

5 MAINTENANCE

5.1 Safety and maintenance frequency

Guidelines for safe maintenance practices, required frequency, and personal protective equipment.