EasyManua.ls Logo

EemaX FlowCo SPEX48 - User Manual

EemaX FlowCo SPEX48
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION GUIDE AND OWNER’S MANUAL
FlowCo™
ELECTRIC INSTANTANEOUS WATER HEATERS

Questions and Answers

  • A
    Amy KramerAug 18, 2025
    What to do if EemaX FlowCo SPEX48 Water Heater has undervoltage?
    • R
      Rachel GonzalezAug 18, 2025
      If your EemaX Water Heater is experiencing undervoltage, it indicates that the inlet voltage is too low compared to the heater's specifications. Provide voltage within specified range.
  • L
    Lynn AdamsAug 20, 2025
    Why is my EemaX FlowCo SPEX48 producing low heat?
    • N
      Nancy MendezAug 20, 2025
      Low heat from your EemaX Water Heater can occur for several reasons: - The outlet temperature is below 90°F/32°C for 5 seconds of flow. - Element failure. - ECO tripped or malfunctioning. - Relay/contactor malfunctioning. - Control board failure. - Inlet water supply out of spec. To attempt a fix, reduce the flow through the unit.
  • W
    William BenderAug 23, 2025
    What to do if EemaX FlowCo SPEX48 Water Heater flow is too high?
    • J
      joseblackAug 23, 2025
      If the flow in your EemaX Water Heater is too high, preventing the water from heating to the setpoint temperature, reduce the flow. You can achieve this by using an outlet flow restrictor or a faucet aerator.
  • T
    Theodore DixonAug 26, 2025
    What to do if EemaX FlowCo SPEX48 Water Heater shows freeze warning?
    • M
      Michelle SheaAug 26, 2025
      If your EemaX Water Heater displays a freeze warning, it means the inlet temperature is too low (below 35°F). To resolve this, increase the temperature of the inlet water to meet product specifications.
  • J
    Jeffrey JohnsonAug 28, 2025
    What to do if EemaX FlowCo SPEX48 Water Heater has overvoltage?
    • S
      scott60Aug 28, 2025
      If your EemaX Water Heater is experiencing overvoltage, it means the inlet voltage is too high compared to the heater's specifications. Provide voltage within specified range.
  • S
    scott53Aug 30, 2025
    What causes residual heat in EemaX FlowCo SPEX48 Water Heater?
    • L
      Laurie WilliamsAug 30, 2025
      Residual heat in your EemaX Water Heater, indicated by an elevated internal water temperature without flow, is caused by both triacs failing closed. To solve this, run water through the unit.
  • A
    Austin JacksonSep 2, 2025
    What to do if EemaX Water Heater has inlet thermistor failure?
    • K
      kellerwandaSep 2, 2025
      If your EemaX Water Heater is showing an inlet thermistor failure, this is because the inlet thermistor is interrupted or disconnected. Inspect the connections/wiring of the inlet thermistor.
  • R
    Renee BarnettSep 4, 2025
    What to do if EemaX FlowCo SPEX48 has outlet thermistor failure?
    • H
      Heather WestSep 4, 2025
      If your EemaX Water Heater is showing an outlet thermistor failure, this is because the outlet thermistor is interrupted or disconnected. Inspect connections/wiring of outlet thermistor.
  • M
    Michelle NewtonSep 7, 2025
    What to do if EemaX FlowCo SPEX48 Water Heater has over-temperature protection?
    • S
      Stephen EdwardsSep 7, 2025
      If the outlet temperature of your EemaX Water Heater exceeds 130°F/54°C, it triggers over-temperature protection. To resolve this, increase the water flow through the unit. This will help decrease the overall temperature rise.
  • C
    Casey BurnettSep 9, 2025
    What to do if EemaX FlowCo SPEX48 shows an over-temperature warning?
    • R
      Roger HahnSep 9, 2025
      If the outlet temperature of your EemaX Water Heater exceeds 110°F/38°C, it triggers an over-temperature warning. To address this, increase the flow through the unit. If you desire this temperature, no action is required.

Summary

Important Safety Instructions

Read and Follow All Instructions

Emphasizes the importance of following all installation and safety guidelines for the appliance.

Mounting the Unit to the Wall

Plumbing Hook-Up

Electrical Hook-Up

Electrical Specifications

Details voltage, power, current, and recommended minimum wire size for various models.

Commissioning the Heater

Troubleshooting

Periodic Maintenance

Replacement Part Numbers

Compression Fittings

Lists part numbers for essential compression fittings like nuts and sleeves.

Repair Parts for Flowco Units

EemaX FlowCo SPEX48 Specifications

General IconGeneral
BrandEemaX
ModelFlowCo SPEX48
CategoryWater Heater
LanguageEnglish