INSTALLATION GUIDE AND OWNER’S MANUAL
FlowCo™
ELECTRIC INSTANTANEOUS WATER HEATERS

Questions and Answers

  • R
    Robert ReyesAug 18, 2025
    What to do if EemaX FlowCo SPEX95 Water Heater has undervoltage?
    • E
      Emily LeeAug 18, 2025
      If your EemaX Water Heater is experiencing undervoltage, it indicates that the inlet voltage is too low compared to the heater's specifications. Provide voltage within specified range.
  • M
    Megan OrtizAug 20, 2025
    Why is my EemaX FlowCo SPEX95 Water Heater producing low heat?
    • H
      Heidi AdamsAug 21, 2025
      Low heat from your EemaX Water Heater can occur for several reasons: - The outlet temperature is below 90°F/32°C for 5 seconds of flow. - Element failure. - ECO tripped or malfunctioning. - Relay/contactor malfunctioning. - Control board failure. - Inlet water supply out of spec. To attempt a fix, reduce the flow through the unit.
  • E
    erodgersAug 22, 2025
    What to do if EemaX Water Heater flow is too high?
    • R
      robertscherylAug 22, 2025
      If the flow in your EemaX Water Heater is too high, preventing the water from heating to the setpoint temperature, reduce the flow. You can achieve this by using an outlet flow restrictor or a faucet aerator.
  • C
    carloslawrenceAug 26, 2025
    What to do if EemaX FlowCo SPEX95 Water Heater shows freeze warning?
    • K
      kevingreenAug 26, 2025
      If your EemaX Water Heater displays a freeze warning, it means the inlet temperature is too low (below 35°F). To resolve this, increase the temperature of the inlet water to meet product specifications.
  • C
    Carolyn SantosAug 28, 2025
    What to do if EemaX FlowCo SPEX95 Water Heater has overvoltage?
    • J
      Joshua CannonAug 28, 2025
      If your EemaX Water Heater is experiencing overvoltage, it means the inlet voltage is too high compared to the heater's specifications. Provide voltage within specified range.
  • D
    dylan48Aug 30, 2025
    What causes residual heat in EemaX FlowCo SPEX95?
    • E
      eric58Aug 30, 2025
      Residual heat in your EemaX Water Heater, indicated by an elevated internal water temperature without flow, is caused by both triacs failing closed. To solve this, run water through the unit.
  • J
    jennifer13Sep 1, 2025
    What to do if EemaX FlowCo SPEX95 has inlet thermistor failure?
    • R
      robert29Sep 2, 2025
      If your EemaX Water Heater is showing an inlet thermistor failure, this is because the inlet thermistor is interrupted or disconnected. Inspect the connections/wiring of the inlet thermistor.
  • D
    David PhamSep 4, 2025
    What to do if EemaX FlowCo SPEX95 has outlet thermistor failure?
    • D
      Dr. Alexis HernandezSep 5, 2025
      If your EemaX Water Heater is showing an outlet thermistor failure, this is because the outlet thermistor is interrupted or disconnected. Inspect connections/wiring of outlet thermistor.
  • M
    Mrs. Jennifer LongSep 6, 2025
    What to do if EemaX FlowCo SPEX95 has over-temperature protection?
    • D
      Dennis KimSep 7, 2025
      If the outlet temperature of your EemaX Water Heater exceeds 130°F/54°C, it triggers over-temperature protection. To resolve this, increase the water flow through the unit. This will help decrease the overall temperature rise.
  • E
    Emily AtkinsonSep 9, 2025
    What to do if EemaX Water Heater shows an over-temperature warning?
    • M
      Michael BanksSep 9, 2025
      If the outlet temperature of your EemaX Water Heater exceeds 110°F/38°C, it triggers an over-temperature warning. To address this, increase the flow through the unit. If you desire this temperature, no action is required.

Summary

Important Safety Instructions

General Information

Mounting the Unit to the Wall

Plumbing Hook-Up Instructions

Electrical Hook-Up Guide

Commissioning the Heater

Troubleshooting Guide

Periodic Maintenance Procedures

Replacement Part Numbers

FlowCo Unit Repair Parts

EemaX FlowCo SPEX95 Specifications

General IconGeneral
Power9.5 kW
Voltage240 V
Required Breaker40 A
Wire Size8 AWG
Water Connection3/4" NPT