INSTALLATION GUIDE AND OWNER’S MANUAL
FlowCo™
ELECTRIC INSTANTANEOUS WATER HEATERS

Questions and Answers

  • D
    Dana RodriguezSep 12, 2025
    What to do if my EemaX FlowCo SPEX95 Water Heater shows a freeze warning?
    • D
      Diane StaffordSep 12, 2025
      A freeze warning on your EemaX Water Heater indicates that the inlet temperature is too low (below 35°F/2°C). To resolve this, increase the temperature of the inlet water to meet product specifications.
  • J
    Jo DunnSep 14, 2025
    How to fix outlet thermistor failure in EemaX FlowCo SPEX95?
    • T
      Tina SanchezSep 14, 2025
      An outlet thermistor failure in your EemaX Water Heater is caused by an interrupted or disconnected outlet thermistor. Inspect the connections and wiring of the outlet thermistor to resolve this issue.

Summary

Important Safety Instructions

General Information

Mounting the Unit to the Wall

Plumbing Hook-Up Instructions

Electrical Hook-Up Guide

Commissioning the Heater

Troubleshooting Guide

Periodic Maintenance Procedures

Replacement Part Numbers

FlowCo Unit Repair Parts

EemaX FlowCo SPEX95 Specifications

General IconGeneral
Power9.5 kW
Voltage240 V
Required Breaker40 A
Wire Size8 AWG
Water Connection3/4" NPT