4. Installation
22
10 cm
Then pass the off-heat tube to the exterior. You will need
an opening with a 100 mm diameter.
Be careful of electrical lines when drilling. The RV
manufacturer or your dealer can provide information as
to the location of lines.
Pass the off-heat tube through the opening; any excess
may be shortened.
It may be necessary to use an external face plate to
protect the outlet. Use a suitable sealant to prevent
moisture from penetrating into the body or into the
interior.
4.6
Connecting the Exhaust Hose
Exhaust gasses contain moisture and may exceed
60° C, causing scalding. Exhaust byproducts may
contain injurious substances. Avoid inhaling exhaust
directly or for long periods of time.
The exhaust hose may not be longer than 50 cm in
order to prevent freezing in winter. The hose may be
up to 150 cm long for summer operation and during
transitional seasons.
At no time may siphoning occur in the hose. Make sure
that the hose is neither clogged nor blocked.
Routing the exhaust hose
Up
Down
Avoid siphoning