5. Operation
37
5.11 Storage
Press on the remote control to switch off the unit.
Off
Antifreeze mode
Wait until the unit has shut down and the display has
disappeared (approx. 30 min.).
Unplug the charging line and the data line for the
remote control.
Store the plugs and lines in a cool, dry place.
WARNING
Do not smoke when handling unit and fuel
cartridge. Keep away from open flame!
CAUTION
Unscrew the fuel cartridge and close it with a cap.
Keep all elements clean.
WARNING
Keep unit and fuel cartridges – even empty or
partially empty cartridges – away from children.
Remove the exhaust hose. Keep it clean and place a
cap over the exhaust outlet.
Remove the off-heat tube and the off-heat bow if
necessary and remove the EFOY Pro from the
mounting plate.
CAUTION
Store unit in a cool place; however, the temperature
should exceed 1° C because the automatic antifreeze
feature will only work if a fuel cartridge is attached
along with a sufficiently charged battery. (See
Chapter 5.10, page 36)