EasyManuals Logo

EG4 6000XP GEN BOOST User Manual

EG4 6000XP GEN BOOST
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
©2024 EG4 ELECTRONICS, LLC. ALL RIGHTS RESERVED.
VERSION 1.0 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE.
EG4 6000XP GEN BOOST
This document provides a brief overview of the newly added
“Generator Boost setting via the latest firmware update. This setting
allows the 6000XP to pull supplemental power from both PV and
Battery whenever the generator power is not sufficient to handle all
loads. This setting can be activated via the EG4 Monitor System or the
LCD display.
ACTIVATING GEN BOOST THROUGH EG4 MONITOR CENTER
Follow the steps listed below to activate Generator Boost via Monitor Center:
1. Login to the Monitor Center and select the appropriate station.
2. Navigate to the “Maintenance” tab.
3. Navigate to the “Charge Setting” section.
NOTE: Only installer or distributor accounts are able to
remotely set this function through the EG4 Monitor Center.
Endusers must set this via the LCD display on the front of
the unit.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 6000XP GEN BOOST and is the answer not in the manual?

EG4 6000XP GEN BOOST Specifications

General IconGeneral
Rated Power6000W
Input Voltage120/240VAC
Output Voltage120/240VAC
Efficiency93%
ModelEG4 6000XP GEN BOOST
Max AC Input Current50A
Max Charge Current120A
Max Input Current18A
Surge Power12000W
Frequency60Hz
Maximum DC Voltage500V
Battery Voltage Range40-60V
MPPT Voltage Range120-450V