56-VOLT LITHIUM-ION ELECTRIC ZERO TURN MOWER — ZT5200L/ZT5200L-FC68
LCD
Display
Description
Fault code
on LCD
Mower
Status
Indicator
Audio
Indicator
Cause Solution
see “Fault
code”
Left driv-
ing motor
does not
rotate.
PCBA con-
trolled left
driving motor
fails.
413 OFF One beep PCBA failure
Have repairs performed by a qualied
service technician.
Plug (Triple-
phase, power
wire) connect-
ing the left
driving motor
with the corre-
sponding PCBA
is loosened.
317 OFF One beep
Loose connec-
tion
Have repairs performed by a qualied
service technician.
Plug (Six pins,
signal wire)
connecting
the left driving
motor with the
correspond-
ing PCBA is
loosened.
301 OFF One beep
Loose connec-
tion
Have repairs performed by a qualied
service technician.
Left driving
motor fails.
317 OFF One beep Motor failure
Have repairs performed by a qualied
service technician.
see “Fault
code”
Right
driving
motor
fails in
rotation
PCBA con-
trolled right
driving motor
fails.
313 OFF one beep PCBA failure
Have repairs performed by a qualied
service technician.
Plug (Triple-
phase, power
wire) connect-
ing the right
driving motor
with the corre-
sponding PCBA
is loosened.
417 OFF one beep
Loose connec-
tion
Have repairs performed by a qualied
service technician.
Plug (Six pins,
signal wire)
connecting the
right driving
motor with the
correspond-
ing PCBA is
loosened.
401 OFF one beep
Loose connec-
tion
Have repairs performed by a qualied
service technician.
Right driving
motor fails.
417 OFF one beep Motor failure
Have repairs performed by a qualied
service technician.

Table of Contents