EHC Fusion E10 Combi Installation and technical manual Page 7
6. Technical specifications________________________
General
Boiler range
9 kW 12 kW 14.4 kW
Cylinder
Heating output 30,717 Btu 40,956 Btu 49,147 Btu
Electricity Supply 230/240V single phase 50Hz
Load/Current 39.1 Amps 52.2 Amps 62.6 Amps
Protection required 45.0 Amps 63.0 Amps 80.0 Amps
CH Max temp setting
Factory setting
85°C 55/60°C
CH Min temp setting 40°C 25°C
CH Overheat protection 100°C
Pump included Yes
Recommended pump
setting
Maximum
CH Flow and Return pipes 22mm
Domestic & Primary
connections
22mm
Min Water Pressure 1.0 Bar 3.0 Bar
Max Water Pressure 3.0 Bar 7.0 Bar
Expansion Vessels 8 litre 12 litre
Back up immersion heater 3.0 kW
Performance
150 litre
9 kW 12 kW 14.4 kW
Time to re-heat from 15C to
56C
63 mins 47 mins 38 mins
180 litre
9 kW 12 kW 14.4 kW
Time to re-heat from 15C to
56C
79 mins 59 mins 48 mins