EasyManua.ls Logo

EINHELL GC-AW 1136 - User Manual

EINHELL GC-AW 1136
88 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Art.-Nr.: 41.767.16 I.-Nr.: 11013
GC-AW
113 6
k
Originalbetriebsanleitung
Hauswasserautomat
t
Original operating instructions
Automatic Domestic Water System
p
Mode d’emploi d’origine
Système automatique d’eau à emploi
domestique
C
Istruzioni per l’uso originali
Centralina idrica automatica
U
Original-bruksanvisning
Pumpautomat
q
Alkuperäiskäyttöohje
Kotitalousvesiautomaatti
Z
Orijinal Kullanma Talimatı
Hidrofor
O
Manual de instruções original
Bomba de rega automática
z
Πρωτότυπες Οδηγίες χρήσης
Aυτόματη συσκευή νερού οικιακής χρήσης
N
Originele handleiding
automatische watervoorzieningsinstallatie
j
Originální návod k obsluze
Automatická domácí vodárna
W
Originálny návod na obsluhu
Domáci vodný automat
Q
Instrucţiuni de utilizare originale
Hidrofor automat
Anleitung_GC_AW_1136_SPK7__ 04.09.13 16:14 Seite 1

Table of Contents

Questions and Answers

  • K
    Kelly GardnerAug 10, 2025
    What to do if my EINHELL GC-AW 1136 motor fails to start up?
    • A
      Adriana Johnson MDAug 11, 2025
      If the motor fails to start, there could be a couple of reasons. First, check the mains voltage to ensure that the pump is receiving power. Second, the pump rotor might be blocked. If this is the case, dismantle and clean the pump.
  • C
    Christopher DavisAug 17, 2025
    Why is my EINHELL GC-AW 1136 Water Pump not intaking water?
    • M
      mfloresAug 17, 2025
      There are several reasons why your EINHELL Water Pump might not be intaking water. Here's what to check: * Ensure the intake valve is submerged in water. * If the pump chamber lacks a water connection, remove the coarse filter with the non-return valve, then fill water into the pump housing. * Make sure the intake line is airtight to prevent air leaks. * Clean the intake valve to ensure it's not leaking. * Check and clean the strainer (intake valve) if it's blocked. * Verify that the maximum suction height has not been exceeded.
  • K
    Kevin ZimmermanAug 25, 2025
    What to do if my EINHELL GC-AW 1136 Water Pump has an inadequate delivery rate?
    • J
      James SanchezAug 26, 2025
      If your EINHELL Water Pump has an inadequate delivery rate, consider the following: * Check if the suction height is too high. * Clean the coarse filter if it's dirty. * If the water level is falling rapidly, place the suction hose at a deeper level. * If contaminants have diminished the pump's performance, clean the pump and replace any worn parts.
  • K
    kjonesSep 2, 2025
    Why does thermostat switch off my EINHELL Water Pump?
    • M
      Michael RiversSep 2, 2025
      The thermostat might be switching off your EINHELL Water Pump because the motor is overloaded, in this case you should dismantle and clean pump. Another possible cause is excessive friction from foreign substances. To address this, prevent the intake of foreign substances by using a filter.