EasyManuals Logo

EINHELL GC-GP 6040 ECO User Manual

EINHELL GC-GP 6040 ECO
Go to English
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
GB
- 20 -
11. Troubleshooting guide
Faults Cause Remedy
Motor fails to start
up
- No mains voltage
- Pump rotor blocked -thermostat
switched o
- Check voltage
- Dismantle and clean pump
No intake - Intake valve not in water
- Pump chamber without water con-
nection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- Immerse intake valve in water
- Fill water into intake
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery
rate
- Suction height too high
- Strainer dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Check suction height
- Clean strainer
- Immerse intake valve deeper
- Clean pump and replace wearing
Thermostat swit-
ches pump o
- Motor overloaded - friction caused
by foreign substances too high
- Dismantle and clean pump. Prevent
intake of foreign substances ( lter)
Anl_GC_GP_6040_ECO_SPK9.indb 20Anl_GC_GP_6040_ECO_SPK9.indb 20 30.01.2019 09:15:1530.01.2019 09:15:15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GC-GP 6040 ECO and is the answer not in the manual?

EINHELL GC-GP 6040 ECO Specifications

General IconGeneral
BrandEINHELL
ModelGC-GP 6040 ECO
CategoryWater Pump
LanguageEnglish

Related product manuals