10. Troubleshooting guide
Fault Possible cause Remedy
The motor does not
start
a) Equipment not switched on
b) Connections on motor loose
c) Battery not correctly inserted
a) Turn On/Off switch to “I” (see
6.)
b) Have the equipment checked
by a customer service work-
shop
c) Remove battery and reinsert
(see 5.)
The equipment
does not spray, or
only sprays at re-
duced power, even
though the tank
is full
a) Nozzle completely or partly clogged
b) Liquid too viscous and therefore unsui-
table
a) Clean the nozzle (see 7.2)
b) Remove liquid, clean equip-
ment and container (see 7.)
Too much spray
mist
a) Distance from object is too great
b) Spray width too great
a) Reduce spraying distance
b) Reduce spray width (see
6.3.2)
Motor stops sud-
denly
Battery spent Insert a charged battery (see
5.3)