7 TECHNICAL SPECIFICATION
Model
Model
e
S
Model T
f
Measurement
Range
-200°C to 1300°C (-328°F to 2372°F)
Operating
Temperature
Logger only: -30°C to 65°C (-22°F to 149°F)
g
Max : 250°C (482°F)
for 50 minutes
g
Max : 300°C (572°F)
for 30 minutes
5°C to 500°C: ±0.5°C (41°F to 932°F: ±1.0°F)
> 500°C: ±1.0°C (> 932°F: ±2.0°F)
Accuracy
Number of
Channels
6
Measuring
Intervals
Adjustable from 8 per second to 1 per hour
Memory
260,000 readings or 8 production runs
Power Supply
2 x AA batteries
Dimensions
Logger only: 153 x 101 x 23mm (6 x 4 x 0.9")
245 x 245 x 115mm (9.65 x 9.65 x 4.5")
Weight
Logger only: 450g (15.8oz)
4kg (8.8lb)
6kg (13.2lb)
www.elcometer.com
en-11
R
6 WARRANTY STATEMENT
The Elcometer 215 Oven Data Logger and temperature probes are
supplied with a 12 month warranty against manufacturing defects,
excluding contamination and wear.