33
Program
Group 7 - Setting programs
Adjustableparameters
The dryer ends the cooling down program when the chosen time has run out (3 min.) and
when the chosen temperature (45°C) is reached.
Cooling down temperature for programmes P1 - P9
Factory settingPara-
meter /
group
7 46 Cooling down P1 30-85°C / 85-185°F 1 45 45 45 45 45
7 47 Cooling down P2 30-85°C / 85-185°F 1 45 45 45 45 45
7 48 Cooling down P3 30-85°C / 85-185°F 1 45 45 45 45 45
7 49 Cooling down P4 30-85°C / 85-185°F 1 45 45 45 45 45
7 50 Cooling down P5 30-85°C / 85-185°F 1 45 45 45 45 45
7 51 Cooling down P6 30-85°C / 85-185°F 1 45 45 45 45 45
7 52 Cooling down P7 30-85°C / 85-185°F 1 45 45 45 45 45
7 53 Cooling down P8 30-85°C / 85-185°F 1 45 45 45 45 45
7 54 Cooling down P9 30-85°C / 85-185°F 1 45 45 45 45 45
Designation Range Step
Coin AHL
Auto-
Stop
AHL OPL
Auto-
Stop
OPL
RMC
Cooling down times for programmes P1 - P9
Factory settingPara-
meter /
group
7 55 Cooling down P1 1 - 20 min. 1 3 3 3 3 3
7 56 Cooling down P2 1 - 20 min. 1 3 3 3 3 3
7 57 Cooling down P3 1 - 20 min. 1 3 3 3 3 3
7 58 Cooling down P4 1 - 20 min. 1 3 3 3 3 3
7 59 Cooling down P5 1 - 20 min. 1 3 3 3 3 3
7 60 Cooling down P6 1 - 20 min. 1 3 3 3 3 3
7 61 Cooling down P7 1 - 20 min. 1 3 3 3 3 3
7 62 Cooling down P8 1 - 20 min. 1 3 3 3 3 3
7 63 Cooling down P9 1 - 20 min. 1 3 3 3 3 3
Designation Range Step
Coin AHL
Auto-
Stop
AHL OPL
Auto-
Stop
OPL
RMC
= Setting is not relevant
= Setting is not relevant