41
Troubleshooting
Error codes overview
Error Description
code
E 01 Not in use
E 02 Not in use
E 03 The input sensor has short circuited
The thermistor that measures air temperature at the drum inlet or the wires running to
the sensor has short circuited.
E 04 The output sensor has short circuited
The thermistor that measures air temperature at the drum outlet or the wires running
to the sensor has short circuited.
E 05 The fan motor has overheated (Motor 1)
The heat protection contact in the motor, or its cable stem, is open.
E 06 The drum motor has overheated (Motor 2)
The heat protection contact in the motor, or its cable stem, is open.
E 07 External error
E 08 Machine overheated
Protection thermostats for inlet and outlet air.
One of the protection thermostats has opened due to overheating.
E 09 Filter lid open
E 10 Incorrect programming
One or more parameters are incorrect or is missing.
E 11 Drying error with RMC program
The longest permitted RMC time has been exceeded.
(Applies only to machines with RMC).
E 12 Drying error with autostop program
The longest permitted automatic stop time has been exceeded.
(Applies only to machines with automatic stop).
E 13 Drying error with time program
The set drying time is longer than longest permitted.
(Applies to tumble dryers that are connected to a payment system).
E 14 Gas error, push gas reset button
No flame has been detected. (Applies only to gas heated tumble dryers).
E 15 No vacuum detected
The vacuum/pressure switch does not close within 12 seconds of the tumble
dryer starting.
E 16 Vacuum sensor has short circuited
The vacuum/pressure switch was already closed when an attempt was made
to start the tumble dryer.
E 17 The input sensor has disconnected
The inlet thermistor, or its wires, is open.
E 18 The output sensor has disconnected
The outlet thermistor, or its wires, is open.