Troubleshooting
E 18 - The output sensor has disconnected
Error description
This error is displayed when the outlet NTC sensor is disconnected.
This error code can be bypassed. This may need to be done if the machine is sited in a
location where external temperatures are very low.
Error analysis
E – 18
Measure the resistance on
the NTC sensor between
P18-5 and P18-6 on PCB.
Is the resistance between
4kΩ and 6kΩ at 20°C
(68°F)?
Replace NTC sensor
or harness.
Go to step 2.
NO
YES
1. Defective NTC
sensor/harness?
Resetting
Resetting is done by opening/closing the dryer loading door and pressing the start
button
Alternative
Measure voltage between GND and T1
0
10
20
30
40
50
60
70
80
90
100
0
C
1 2 3 4 5 T1 (V)
T2 T1 GND
2. Defective
circuit board?
Replace the circuit board.