EasyManuals Logo

Elektro-Automatik PS 2000 B Triple Series User Manual

Elektro-Automatik PS 2000 B Triple Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Page 26
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
PS 2000 B Triple Series
3.5 Remote control
3.5.1 EA Power Control
The included USB stick contains the Windows software EA Power Control which can remotely control the device.
Also see the user manual of the software.
3.5.2 Programming
Programming details and the communication protocol are to be found in the programming documentation which
is supplied on the included USB stick or which is available as download from the EA Elektro-Automatik website.
3.5.3 EasyPS2000
TheWindowssoftwareEasyPS2000,aso󰀨eredfortheformerPS2000BdesigngenerationwithblueLCD,is
still available and can also be used with the new design generation with color TFT, but it would still depict the
counterfeit of the old design.
3.6 Alarms and monitoring
3.6.1 Device alarm and event handling
AdevicealarmincidentwillusuallyleadtoDCoutputswitch-o󰀨andtheappearanceofa
text message in the display to make the user aware. Some alarms must be acknowledged.
If the condition persists, the display remains and the alarm can only be acknowledged
after elimination of the cause.
How to acknowledge an alarm in the display (during manual control)
1. Once an alarm is indicated, the user can try to acknowledge and delete the alarm by pressing button On/O󰀨.
In order to acknowledge an alarm during remote control, see the programming guide.
Thesedevicealarmsarecongurable:
Alarm Meaning Description Range Indication
OVP
OverVoltage
Protection
Triggers an alarm if the DC output voltage reaches the
denedthreshold.TheDCoutputwillbeswitchedo󰀨..
0 V...1.1*U
Nom
Display, digital
interface
OCP
OverCurrent
Protection
Triggers an alarm if the DC output current reaches the
denedthreshold.TheDCoutputwillbeswitchedo󰀨..
0 A...1.1*I
Nom
Thesedevicealarmscan’tbeconguredandarebasedonhardware:
Alarm Meaning Description Indication
OT
OverTem-
perature
Triggers an alarm if the internal temperature exceeds a certain limit.
TheDCoutputwillbeswitchedo󰀨.
Display, digital
interface
How to congure the device alarms
1. WhiletheDCoutputisswitchedo󰀨,pressbuttonSettings.
2. In the menu use the left knob to navigate to Settings and press the knob.
3. In menu Settings use the left knob again to select OVP (threshold of the overvoltage protection) or OCP
(threshold of the overcurrent protection). Adjust the value as desired.
These protection threshold are always adjustable in their full range of 0...110% of the rated val-
ue. The device permanently compares the actual voltage and current on the DC output against
these thresholds and thus an OVP alarm could also occur while the DC output is switched o.
In this situation the voltage that triggers the OVP must come from outside and could damage
the device.

Table of Contents

Other manuals for Elektro-Automatik PS 2000 B Triple Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elektro-Automatik PS 2000 B Triple Series and is the answer not in the manual?

Elektro-Automatik PS 2000 B Triple Series Specifications

General IconGeneral
BrandElektro-Automatik
ModelPS 2000 B Triple Series
CategoryPower Supply
LanguageEnglish

Related product manuals