Drive control output configuration (Relays)
R8/5 = 0 2 speeds, independent outputs for speed and direction
Output signals ST4=X/ST6=Y 1/5 2/6 3/7 4/8
Creep forwards
X X
Slow forwards
X X
Fast forwards
X X
Creep reverse
X X
Slow reverse
X X
Fast reverse
X X
X = output activated
R8/5 = 1 2 speeds, independent outputs for speed and additional reverse signal
Output signals ST4=X/ST6=Y 1/5 2/6 3/7 4/8
Creep forwards
X X
Slow forwards
X X
Fast forwards
X X
Creep reverse
X X X
Slow reverse
X X X
Fast reverse
X X X
X = output activated
R8/5 = 2 2 speeds, separate outputs for each condition
Output signals ST4=X/ST6=Y 1/5 2/6 3/7 4/8
Creep forwards
X
Slow forwards
X
Fast forwards
X
Creep reverse
X
Slow reverse
X
Fast reverse
X
X = output activated
R8/5 = 3 3 speeds, additional reverse output ( - Standard setting)
Output signals ST4=X/ST6=Y 1/5 2/6 3/7 4/8
Creep forwards
X
Slow forwards
X X
Fast forwards
X X X
Creep reverse
X X
Slow reverse
X X X
Fast reverse
X X X X
X = output activated
R8/5 = 4
2 speeds, independent outputs for speed and direction
Output signals ST4=X/ST6=Y 1/5 2/6 3/7 4/8
Creep forwards
X X
Slow forwards
X X
Fast forwards
X X
Creep reverse
X X
Slow reverse
X X
Fast reverse
X X X
X = output activated