PAR
EW961 EW971 EW974
U.M. Level
RANGE DEFAULT RANGE DEFAULT RANGE DEFAULT
PAO 0 ... 10 0 0 ... 10 0 0 ... 10 0 hours 2
dAO 0 ... 999 0 0 ... 999 0 0 ... 999 0 min 2
OAO 0 ... 10 0 0 ... 10 0 0 ... 10 0 hours 2
tdO 0 ... 250 0 0 ... 250 0 0 ... 250 0 min 2
tAO 0 ... 250 0 0 ... 250 0 0 ... 250 0 min 1&2
dAt --- --- n/y n n/y n ag 2
EAL n/y n n/y n n/y n ag 2
dEA 0 ... 14 0 0 ... 14 0 0 ... 14 0 num 2
FAA 0 ... 14 0 0 ... 14 0 0 ... 14 0 num 2
LOC n/y n n/y n n/y n ag 1&2
PS1 0 ... 250 0 0 ... 250 0 0 ... 250 0 num 1&2
PS2 0 ... 250 15 0 ... 250 15 0 ... 250 15 num 2
ndt n/y y n/y y n/y y ag 2
CA1 -12,0 ... +12,0 0,0 -12,0 ... +12,0 0,0 -12,0 ... +12,0 0,0 °C/°F 1&2
CA2 --- --- -12,0 ... +12,0 0,0 -12,0 ... +12,0 0,0 °C/°F 1&2
ddL 0/1/2 1 0/1/2 1 0/1/2 1 num 1&2
dro 0/1 0 0/1 0 0/1 0 ag 2
ddd 0/1/2 1 0/1/2 1 0/1/2 1 num 2
H08 0/1/2 2 0/1/2 2 0/1/2 2 num 2
H11 -6 ... +6 0 -6 ... +6 0 -6 ... +6 0 num 2
H25 --- --- --- --- 0 ... 6 4 num 2
H32 0 ... 4 0 0 ... 4 0 0 ... 4 0 num 2
H42 --- --- n/y y n/y y ag 1&2
rEL / / / / / / / 1&2
tAb / / / / / / / 1&2
UL / / / / / / / 2
Fr / / / / / / / 2