EasyManua.ls Logo

Elkay LZWSM8K User Manual

Elkay LZWSM8K
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
98557C (Rev. N - 09/16)
Installation/Care/Use Manual
EZH20 In Wall Bottle Filling Station
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND
OTHER APPLICABLE CODES. After installation, leave these instructions inside the
fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE
MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING
SYSTEM. WE SUGGEST THAT THE BOTTLE FILLER BE PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTER (GFCI)
Fig. 2Fig. 1
Installer
LZWSM8* LZWSMD* LZWSM8P* LZWSMDP*
EZWSM8* EZWSMD* EZWSM8P* EZWSMDP*
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
Question and Answer IconNeed help?

Do you have a question about the Elkay LZWSM8K and is the answer not in the manual?

Elkay LZWSM8K Specifications

General IconGeneral
BrandElkay
ModelLZWSM8K
CategoryWater Dispenser
LanguageEnglish

Summary

Installation Overview and Safety

Important Installer Notes

Crucial safety and installation advice, including grounding and material recommendations for installers.

Quick Connect Fitting Operation

Visual guide and instructions for connecting and disconnecting water lines using quick fittings.

Rough-in Dimensions: LZWSM8/LZWSMD Models

Rough-in Dimensions: LZWSM8P/LZWSMDP Models

Step-by-Step Installation Process

Filter and Chiller Water Line Connections

Guidance on connecting filter kits, chillers, and water lines, including flushing procedures.

Control Board Programming and Settings

Filter Monitor and IR Sensor Adjustment

Procedures for resetting the filter monitor and adjusting the IR sensor range for accurate dispensing.

Bottle Count, Unit Type, and Filter Size Configuration

Instructions for resetting bottle count, setting unit type, and selecting filter capacity for optimal performance.

Parts Identification and Replacement Kits